Workplace protection factors-supplied air hood

被引:7
作者
Nelson, TJ
Wheeler, TH
Mustard, TS
机构
[1] NIHS Inc, Ardentown, DE USA
[2] 72 AMDS SGPB, Tinker AFB, OK 73145 USA
[3] Parsons Engn Sci Inc, Denver, CO 80290 USA
来源
AIHAJ | 2001年 / 62卷 / 01期
关键词
ANSI Z88.2; respirators; strontium chromate; workplace protection factor;
D O I
10.1080/15298660108984615
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Several organizations list assigned protection factors. For supplied air hoods, the value of the assigned protection factors varies from <10 to 2000 depending on the organization. Workplace protection factors (WPFs) of a supplied air hood were measured during aircraft sanding and painting operations on several types of aircraft to evaluate whether the American National Standard Z88.2 (1992) assigned protection factor of 1000 was realistic. The primary contaminant during these activities is strontium chromate. Samples collected inside the hood show that employees during sanding and painting operations were not exposed to strontium. The respirator performed adequately. This study is consistent with other simulated and WPF studies in that the ANSI Z88.2 WPF of 1000 is supported.
引用
收藏
页码:96 / 99
页数:4
相关论文
共 13 条
[1]  
*AM IND HYG ASS RE, 1985, AM IND HYG ASSOC J, V46, pB22
[2]  
American National Standard Institute, 1992, Z882 ANSI
[3]  
COLTON CE, 1993, AM IND HYG C EXP NEW
[4]  
JOHNSTON AR, 1992, AM IND HYG ASSOC J, V53, P705, DOI 10.1202/0002-8894(1992)053<0705:RORPTI>2.0.CO
[5]  
2
[6]  
JOHNSTON AR, 1987, AM IND HYG C MONTR C
[7]  
KEYS DR, 1990, AM IND HYG C EXP ORL
[8]  
LIU BYU, 1984, AM IND HYG ASSOC J, V45, P278, DOI 10.1080/15298668491399785
[9]  
MYERS WR, 1984, AM IND HYG ASSOC J, V45, P681, DOI 10.1202/0002-8894(1984)045<0681:WPFMOP>2.3.CO
[10]  
2