Subarachnoid catheter placement after wet tap for analgesia in labor: Influence on the risk of headache in obstetric patients

被引:87
作者
Ayad, S
Demian, Y
Narouze, SN
Tetzlaff, JE
机构
[1] Cleveland Clin Fdn, Ctr Anesthesiol Educ, Cleveland, OH 44195 USA
[2] Fairview Hosp, Cleveland Clin Hlth Syst, Dept Anesthesiol, Cleveland, OH USA
关键词
anesthesia; epidural; wet tap; postdural puncture headache; subarachnoid catheter;
D O I
10.1016/S1098-7339(03)00393-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: The incidence of postdural puncture headache (PDPH) after epidural wet tap for obstetric patients may be as high as 75%. We have studied how subsequent placement of a subarachnoid catheter immediately after confirmation of a wet tap, and leaving the catheter in place for 24 hours affects the incidence of PDPH. Methods: Over a 5-year interval, 115 consecutive patients who had unintentional dural puncture were divided into 3 groups by consecutive assignment. Group A had an epidural catheter placed at another interspace. Group B had a subarachnoid catheter placed for labor analgesia that was removed immediately after delivery. Group C had a subarachnoid catheter that was left in place for 24 hours after delivery. Data were collected retrospectively. The incidence of PDPH and blood patch was compared between groups. Results: The overall incidence of PDPH was 46.9% and need for blood patch 36.5%, significantly less in both subarachnoid catheter groups, 31% in B and 3% in group C, compared with group A (PDPH 81%) (P < .001). Conclusion: Subarachnoid catheter placement after wet tap in obstetric patients reduces the PDPH rate and does so to a greater extent if left in place for 24 hours after delivery.
引用
收藏
页码:512 / 515
页数:4
相关论文
共 12 条
[1]   COMPARISON OF EPIDURAL SALINE PLACEMENT AND EPIDURAL BLOOD PLACEMENT IN TREATMENT OF POST-LUMBAR-PUNCTURE HEADACHE [J].
BART, AJ ;
WHEELER, AS .
ANESTHESIOLOGY, 1978, 48 (03) :221-223
[2]   Pharmacologic management of postdural puncture headache [J].
Choi, A ;
Laurito, CE ;
Cunningham, FE .
ANNALS OF PHARMACOTHERAPY, 1996, 30 (7-8) :831-839
[3]   DECREASED INCIDENCE OF HEADACHE AFTER ACCIDENTAL DURAL PUNCTURE IN CESAREAN DELIVERY PATIENTS RECEIVING CONTINUOUS POSTOPERATIVE INTRATHECAL ANALGESIA [J].
COHEN, S ;
AMAR, D ;
PANTUCK, EJ ;
SINGER, N ;
DIVON, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1994, 38 (07) :716-718
[4]  
CRAFT JB, 1973, ANESTH ANALG, V52, P228
[5]   Intrathecal catheter insertion during labour reduces the risk of postdural puncture headache [J].
Dennehy, KC ;
Rosaeg, OP .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (01) :42-45
[6]  
DENNY N, 1987, ANESTH ANALG, V66, P791
[7]   Role of needle gauge and tip configuration in the production of lumbar puncture headache [J].
Lambert, DH ;
Hurley, RJ ;
Hertwig, L ;
Datta, S .
REGIONAL ANESTHESIA, 1997, 22 (01) :66-72
[8]  
LIU N, 1993, REGION ANESTH, V18, P110
[9]  
NORRIS MC, 1990, REGION ANESTH, V15, P285
[10]   DURAL TAPS REVISITED - A 20-YEAR SURVEY FROM BIRMINGHAM-MATERNITY-HOSPITAL [J].
STRIDE, PC ;
COOPER, GM .
ANAESTHESIA, 1993, 48 (03) :247-255