Dependence of venous enhancement on the field of view in 3D contrast-enhanced MRA using the elliptical centric view order

被引:8
作者
Fain, SB
Riederer, SJ
机构
[1] Mayo Clin, Magnet Resonance Lab, Rochester, MN 55905 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
MR angiography; elliptical centric view order; MR contrast agents; veins; MR rapid imaging;
D O I
10.1002/mrm.1151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dependence of venous suppression on the acquisition field of view (FOV) in elliptical centric 3D contrast-enhanced magnetic resonance angiography (CE-MRA) is studied theoretically and experimentally. It is hypothesized that a reduced FOV in an arterial phase acquisition results in improved venous suppression. An expression is derived linking the k-space representation of a vein to venous return time and acquisition parameters. For a y x z FOV reduction from 24 cm x 7.2 cm to 18 cm x 3.6 cm, equivalent voxel size, and venous return times ranging from 0-7 s, the mean improvement in venous suppression ranged from 7.0% for the 19-mm-diameter vein to 32,1% in the 6-mm-diameter vein, assuming a step function-shaped venous enhancement profile. Decreased venous enhancement with reduced FOV is also observed for scans with equivalent acquisition times, although the degree of suppression is dependent on the shape of the venous enhancement curve. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:1134 / 1141
页数:8
相关论文
共 22 条
[1]  
Bracewell R., 1984, FOURIER TRANSFORM IT
[2]  
DEBOBELLI F, 1997, RADIOLOGY, V205, P689
[3]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741
[4]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[5]  
Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
[6]  
2-Q
[7]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[8]   Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography [J].
Hany, TF ;
Debatin, JF ;
Leung, DA ;
Pfammatter, T .
RADIOLOGY, 1997, 204 (02) :357-362
[9]   Carotid arteries: Maximizing arterial to venous contrast in fluoroscopically triggered contrast-enhanced MR angiography with elliptic centric view ordering [J].
Huston, J ;
Fain, SB ;
Riederer, SJ ;
Wilman, AH ;
Bernstein, MA ;
Busse, RF .
RADIOLOGY, 1999, 211 (01) :265-273
[10]   Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography [J].
Kim, JK ;
Farb, RI ;
Wright, GA .
RADIOLOGY, 1998, 206 (01) :283-289