The Ocular Blood Flow Tonograph: A new instrument for the measurement of intraocular pressure in rabbits

被引:17
作者
Chidlow, G [1 ]
Nash, MS [1 ]
Crowhurst, C [1 ]
Bron, AJ [1 ]
Osborne, NN [1 ]
机构
[1] UNIV OXFORD,NUFFIELD LAB OPHTHALMOL,OXFORD OX2 6AW,ENGLAND
基金
英国惠康基金;
关键词
intraocular pressure; Ocular Blood Flow Tonograph; manometry; calibration; rabbit; serotonin;
D O I
10.1006/exer.1996.0136
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Ocular Blood Flow Tonograph (OBFT) and Digilab Pneumatonograph (PTG) were calibrated for use on New Zealand White rabbits using a pressure manometer and performing tonometry at varying known pressures. The calibration experiments showed that a good correlation exists between OBFT measurements and manometric readings of IOP. Moreover, no difference between open and closed stopcock measurements were observed, Corrective equations for conversion of OBFT readings to mm Hg are documented. The OBFT was compared with the PTG and the results showed there was no significant difference between the IOP measured by either instrument in a group of rabbits displaying a range of different IOPs. Regression analysis of the data gave a slope of 0.88 and a correlation co-efficient of 0.78. The OBFT proved easier to use than the PTG under restricted lighting conditions. The OBFT was also used to measure the circadian variation in IOP and to measure the IOP after the topical application of prostaglandin E(2) and various serotonergic agonists. The combined data demonstrated that the OBFT is an accurate and reliable tonometer for the measurement of IOP in rabbits. (C) 1996 Academic Press Limited
引用
收藏
页码:463 / 469
页数:7
相关论文
共 23 条
[1]   EXPERIMENTAL CORTICOSTEROID OCULAR HYPERTENSION IN THE RABBIT [J].
BONOMI, L ;
PERFETTI, S ;
NOYA, E ;
BELLUCCI, R ;
TOMAZZOLI, L .
ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1978, 209 (02) :73-82
[2]  
Butt Z, 1995, J Glaucoma, V4, P214
[3]  
CAMRAS CB, 1977, INVEST OPHTH VIS SCI, V16, P1125
[4]  
CHIDLOW G, 1995, INVEST OPHTH VIS SCI, V36, P2238
[5]  
GREGORY DS, 1990, INVEST OPHTH VIS SCI, V31, P715
[6]   CALIBRATION OF THE ALCON APPLANATION PNEUMATONOGRAPH AND PERKINS TONOMETER FOR USE IN RABBITS AND CATS [J].
HAMMOND, BR ;
BHATTACHERJEE, P .
CURRENT EYE RESEARCH, 1984, 3 (09) :1155-1158
[7]   STEROID-INDUCED OCULAR HYPERTENSION IN THE RABBIT - A MODEL USING SUBCONJUNCTIVAL INJECTIONS [J].
HESTER, DE ;
TRITES, PN ;
PEIFFER, RL ;
PETROW, V .
JOURNAL OF OCULAR PHARMACOLOGY, 1987, 3 (03) :185-189
[8]  
JAFFAR MS, 1993, J PEDIATR OPHTHALMOL, V30, P284
[9]   CHARACTERIZATION OF SEROTONIN RECEPTORS IN THE IRIS + CILIARY BODY OF THE ALBINO RABBIT [J].
MALLORGA, P ;
SUGRUE, MF .
CURRENT EYE RESEARCH, 1987, 6 (03) :527-532
[10]   WATER-LOADING TEST IN RABBITS - A METHOD TO DETECT POTENTIAL OCULAR HYPOTENSIVE DRUGS [J].
MCDONALD, TO ;
HODGES, JW ;
BORGMANN, AR ;
LEADERS, FE .
ARCHIVES OF OPHTHALMOLOGY, 1969, 82 (03) :381-&