A rapid three-dimensional vortex micromixer utilizing self-rotation effects under low Reynolds number conditions

被引:107
作者
Lin, CH [1 ]
Tsai, CH
Fu, LM
机构
[1] Natl Sun Yat Sen Univ, Dept Mech & Electromech Engn, Kaohsiung 804, Taiwan
[2] Natl Pingtung Univ Sci & Technol, Dept Vehicle Engn, Pingtung 912, Taiwan
[3] Natl Pingtung Univ Sci & Technol, Grad Inst Mat Engn, Pingtung 912, Taiwan
关键词
D O I
10.1088/0960-1317/15/5/006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a novel three-dimensional (3D) vortex micromixer for micro-total-analysis-systems (mu TAS) applications which utilizes self-rotation effects to mix fluids in a circular chamber at low Reynolds numbers (Re). The microfluidic mixer is fabricated in a three-layer glass structure for delivering fluid samples in parallel. The fluids are driven into the circular mixing chamber by means of hydrodynamic pumps from two fluid inlet ports. The two inlet channels divide into eight individual channels tangent to a 3D circular chamber for the purpose of mixing. Numerical simulation of the microfluidic dynamics is employed to predict the self-rotation phenomenon and to estimate the mixing performance under various Reynolds number conditions. Experimental flow visualization by mixing dye samples is performed in order to verify the numerical simulation results. A good agreement is found to exist between the two sets of results. The numerical results indicate that the mixing performance can be as high as 90% within a mixing chamber of 1 mm diameter when the Reynolds number is Re = 4. Additionally, the results confirm that self-rotation in the circular mixer enhances the mixing performance significantly, even at low Reynolds numbers. The novel micromixing method presented in this study provides a simple solution to mixing problems in the lab-chip system.
引用
收藏
页码:935 / 943
页数:9
相关论文
共 57 条
[1]   Microfluidic separation of DNA [J].
Ashton, R ;
Padala, C ;
Kane, RS .
CURRENT OPINION IN BIOTECHNOLOGY, 2003, 14 (05) :497-504
[2]   Microstructure for efficient continuous flow mixing [J].
Bessoth, FG ;
deMello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1999, 36 (06) :213-215
[3]   Heterogeneous surface charge enhanced micromixing for electrokinetic flows [J].
Biddiss, E ;
Erickson, D ;
Li, DQ .
ANALYTICAL CHEMISTRY, 2004, 76 (11) :3208-3213
[4]  
BOHM S, 2001, MICRO TOTAL ANAL SYS, V1, P25
[5]   MIXING AND FAST CHEMICAL-REACTION .1. TEST REACTIONS TO DETERMINE SEGREGATION [J].
BOURNE, JR ;
KOZICKI, F ;
RYS, P .
CHEMICAL ENGINEERING SCIENCE, 1981, 36 (10) :1643-1648
[6]   Sample filtration, concentration, and separation integrated on microfluidic devices [J].
Broyles, BS ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2761-2767
[7]   Design and theoretical evaluation of a novel microfluidic device to be used for PCR [J].
Bu, MQ ;
Melvin, T ;
Ensell, G ;
Wilkinson, JS ;
Evans, AGR .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) :S125-S130
[8]   Stopped-flow enzyme assays on a chip using a microfabricated mixer [J].
Burke, BJ ;
Regnier, FE .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1786-1791
[9]   Computational analysis of electrokinetically driven flow mixing in microchannels with patterned blocks [J].
Chang, CC ;
Yang, RJ .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (04) :550-558
[10]   Design of passive mixers utilizing microfluidic self-circulation in the mixing chamber [J].
Chung, YC ;
Hsu, YL ;
Jen, CP ;
Lu, MC ;
Lin, YC .
LAB ON A CHIP, 2004, 4 (01) :70-77