Comparison of the chromatography of octadecyl silane bonded silica and polybutadiene-coated zirconia phases based on a diverse set of cationic drugs

被引:52
作者
Dai, J [1 ]
Yang, XQ [1 ]
Carr, PW [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
关键词
stationary phases; LC; silanol activity; column characterization; octadecyl silane bonded silica phase; polybutadiene-coated zirconia phase; cationic drugs;
D O I
10.1016/S0021-9673(03)00929-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we compare the separation of basic drugs on several octadecyl silane bonded silica (ODS) phases and a polybutadiene-coated zirconia (PBD-ZrO2) phase. The retention characteristics were investigated in detail using a variety of cationic drugs as probe solutes. The ODS phases were selected to cover a relatively wide range in silanol activity and were studied with ammonium phosphate eluents at pH 3.0 and 6.0. Compared to any of the ODS phases, the PBD-ZrO2 phase showed very significant differences in selectivities towards these drugs. Due to the presence of both reversed-phase and ion-exchange interactions between the stationary phase and the basic analyte on ODS and PBD-ZrO2, mixed-mode retention takes place to some extent on both types of phases. However, very large differences in the relative contributions from ion-exchange and reversed-phase interactions on the two types of phases led to quite different selectivities. When phosphate is present in the eluent and adsorbs on the surface, the PBD-ZrO2 phase takes on a high negative charge over a wide pH range due to phosphate adsorption on its surface. On ODS phases, ion-exchange interactions result from the interactions between protonated basic compounds and ionized residual silanol groups. Since the pH of the eluent influences the charge state of the silanol groups, the ion-exchange interactions vary in strength depending on pH. At pH 6.0, the ion-exchange interactions are strong. However, at pH 3.0 the ion-exchange interactions on ODS are significantly smaller because the silanol groups are less dissociated at the lower pH. Thus, not only are the selectivities of the ODS and PBD-ZrO2 phases different but quite different trends in retention are observed on these two types of phases as the pH of the eluent is varied. More importantly, by using the large set of "real" basic analytes we show the extreme complexity of the chromatographic processes on the reversed stationary phases. Both the test condition and solute property influence the column performance. Therefore, use of only one or two probe solutes is not sufficient for column ranking. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 82
页数:20
相关论文
共 49 条
[1]   SURFACE SILANOLS IN SILICA-BONDED HYDROCARBONACEOUS STATIONARY PHASES .2. IRREGULAR RETENTION BEHAVIOR AND EFFECT OF SILANOL MASKING [J].
BIJ, KE ;
HORVATH, C ;
MELANDER, WR ;
NAHUM, A .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :65-84
[2]   Retention of ionizable compounds on high-performance liquid chromatography -: III.: Variation of pK values of acids and pH values of buffers in acetonitrile-water mobile phases [J].
Bosch, E ;
Espinosa, S ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :137-146
[3]   Retention of ionizable compounds on HPLC. pH scale in methanol-water and the pK and pH values of buffers [J].
Bosch, E ;
Bou, P ;
Allemann, H ;
Roses, M .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3651-3657
[4]   Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography [J].
Claessens, HA ;
van Straten, MA ;
Cramers, CA ;
Jezierska, M ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :135-156
[5]   Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography [J].
Claessens, HA ;
vanStraten, MA ;
Kirkland, JJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :259-270
[6]  
Dorsey JG, 1996, ANAL CHEM, V68, pR515, DOI 10.1021/a19600202
[7]   Zirconia stationary phases for extreme separations [J].
Dunlap, CJ ;
McNeff, CV ;
Stoll, D ;
Carr, PW .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :598A-607A
[8]   COMPARISON AND CHARACTERIZATION OF REVERSED PHASES [J].
ENGELHARDT, H ;
JUNGHEIM, M .
CHROMATOGRAPHIA, 1990, 29 (1-2) :59-68
[9]  
FORD C, MAC MOD ANAL
[10]  
Haddad P.R., 1990, ION CHROMATOGRAPHY P, DOI DOI 10.1016/S0301-4770(08)61141-0