Clinical performance of a new point-of-care cardiac troponin I assay compared to three laboratory troponin assays

被引:18
作者
Hjortshoj, Soren [1 ]
Venge, Per [2 ,3 ]
Ravkilde, Jan [1 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Cardiovasc Res Ctr, Heart Ctr Aalborg, DK-9000 Aalborg, Denmark
[2] Uppsala Univ, Dept Med Sci, Uppsala, Sweden
[3] Univ Hosp, Dept Clin Chem & Pharmacol, Uppsala, Sweden
关键词
Myocardial infarction; Cardiac markers; Troponins; Point-of-care testing; ACUTE MYOCARDIAL-INFARCTION; ACUTE CORONARY SYNDROME; RANDOMIZED CONTROLLED-TRIAL; BIOCHEMICAL MARKERS; EUROPEAN-SOCIETY; COLLEGE; RECOMMENDATIONS; SENSITIVITY; TIME; UNIT;
D O I
10.1016/j.cca.2010.11.015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Studies of cardiac markers in diagnosing acute myocardial infarction (AMI) have mostly been performed using central laboratory platforms. The AQT90 FLEX TnI (troponin I) assay is designed for quantitative point of care testing (POCT). This study evaluated clinical performance in diagnosing AMI of the AQT90 FLEX TnI POCT assay compared with central laboratory troponin assays. Methods: The study included 458 chest pain patients. Blood samples were obtained on admission and after 69 h. Blood was analyzed using the following assays: AQT90 FLEX TnI, Access AccuTnI, Abbott AxSYM ADV. Roche cTnT, Roche CKMBmass. Patients were diagnosed with AMI according to the new universal definition of AMI. Results: The performance of the AQT90 FLEX TnI assay on admission was equivalent to the Abbott AxSYM ADV cTnI but inferior to the AccuTnI. After 6-9 h both laboratory based assays were superior. The AQT90 FLEX TnI had a negative predictive value (NPV) of 90 and 96% (admission: 6-9 h). No statistical differences were seen in receiver operating characteristics analysis. Conclusions: The AQT90 FLEX TnI POCT assay was marginally inferior to the two laboratory based assays of cTnI in diagnosing AMI. A high (NPV) may make this assay suitable as a rule out marker. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:370 / 375
页数:6
相关论文
共 32 条
[1]  
*ABB DIAGN, 2009, ABB AXZYM SYST TROP
[2]  
[Anonymous], EUR HEART J
[3]  
Apple Fred S, 2007, Circulation, V115, pe352
[4]   Decreased patient charges following implementation of point-of-care cardiac troponin monitoring in acute coronary syndrome patients in a community hospital cardiology unit [J].
Apple, Fred S. ;
Chung, Adrine Y. ;
Kogut, Mary Ellen ;
Bubany, Susan ;
Murakami, MaryAnn M. .
CLINICA CHIMICA ACTA, 2006, 370 (1-2) :191-195
[5]   Point-of-care i-STAT cardiac troponin I for assessment of patients with symptoms suggestive of acute coronary syndrome [J].
Apple, FS ;
Ler, R ;
Chung, AY ;
Berger, MJ ;
Murakami, MM .
CLINICAL CHEMISTRY, 2006, 52 (02) :322-325
[6]   Plasma 99th percentile reference limits for cardiac troponin and creatine kinase MB mass for use with European Society of Cardiology American College of Cardiology consensus recommendations [J].
Apple, FS ;
Quist, HE ;
Doyle, PJ ;
Otto, AP ;
Murakami, MM .
CLINICAL CHEMISTRY, 2003, 49 (08) :1331-1336
[7]   ACC/AHA guidelines for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction [J].
Braunwald, E ;
Antman, EM ;
Beasley, JW ;
Califf, RM ;
Cheitlin, MD ;
Hochman, JS ;
Jones, RH ;
Kereiakes, D ;
Kupersmith, J ;
Levin, TN ;
Pepine, CJ ;
Schaeffer, JW ;
Smith, EE ;
Steward, DE ;
Theroux, P ;
Gibbons, RJ ;
Alpert, JS ;
Eagle, KA ;
Faxon, DP ;
Fuster, V ;
Gardner, TJ ;
Gregoratos, G ;
Russell, RO ;
Smith, SC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :970-1056
[8]   A prospective randomized controlled trial of point-of-care testing on the coronary care unit [J].
Collinson, PO ;
John, C ;
Lynch, S ;
Rao, A ;
Canepa-Anson, R ;
Carson, E ;
Cramp, D .
ANNALS OF CLINICAL BIOCHEMISTRY, 2004, 41 :397-404
[9]   Time delay to treatment and mortality in primary angioplasty for acute myocardial infarction - Every minute of delay counts [J].
De Luca, G ;
Suryapranata, H ;
Ottervanger, JP ;
Antman, EM .
CIRCULATION, 2004, 109 (10) :1223-1225
[10]   High-Sensitivity Cardiac Troponin T for Early Prediction of Evolving Non-ST-Segment Elevation Myocardial Infarction in Patients with Suspected Acute Coronary Syndrome and Negative Troponin Results on Admission [J].
Giannitsis, Evangelos ;
Becker, Meike ;
Kurz, Kerstin ;
Hess, Georg ;
Zdunek, Dietmar ;
Katus, Hugo A. .
CLINICAL CHEMISTRY, 2010, 56 (04) :642-650