Inflow effect correction in fast gradient-echo perfusion imaging

被引:49
作者
Ivancevic, MK
Zimine, I
Montet, X
Hyacinthe, JN
Lazeyras, F
Foxall, D
Vallée, JP
机构
[1] Univ Hosp Geneva, Dept Radiol, UIN, CH-1211 Geneva 14, Switzerland
[2] Philips Med Syst, Cleveland, OH USA
关键词
FAST and RF-FAST MR sequence; perfusion imaging; signal calibration; inflow effect; contrast media;
D O I
10.1002/mrm.10633
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purposes of this study were to assess the extent of the inflow effect on signal intensity (SI) for fast gradient-recalled-echo (GRE) sequences used to observe first-pass perfusion, and to develop and validate a correction method for this effect. A phantom experiment with a flow apparatus was performed to determine SI as a function of Gd-DTPA concentration for various velocities. Subsequently a flow-sensitive calibration method was developed, and validated on bolus injections into an open-circuit flow apparatus and in vivo. It is shown that calibration methods based on static phantoms are not appropriate for accurate signal-to-concentration conversion in images affected by high flow. The flow-corrected calibration method presented here can be used to improve the accuracy and robustness of the arterial input function (AIF) determination for tissue perfusion quantification using MRI and contrast media. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:885 / 891
页数:7
相关论文
共 22 条
[1]  
ABRAGAM A, 1961, PRINCIPLES NUCLEAR M, P300
[2]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[3]   Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage [J].
Bertschinger, KM ;
Nanz, D ;
Buechi, M ;
Luescher, TF ;
Marincek, B ;
von Schulthess, GK ;
Schwitter, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :556-562
[4]   QUANTIFICATION OF T1 VALUES BY SNAPSHOT-FLASH NMR IMAGING [J].
DEICHMANN, R ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (03) :608-612
[5]   Quantification of gadolinium-DTPA concentrations for different inversion times using an IR-turbo flash pulse sequence: A study on optimizing multislice perfusion imaging [J].
Fritz-Hansen, T ;
Rostrup, E ;
Ring, PB ;
Larsson, HBW .
MAGNETIC RESONANCE IMAGING, 1998, 16 (08) :893-899
[7]   FAST sequences optimization for contrast media pharmacokinetic quantification in tissue [J].
Ivancevic, MK ;
Zimine, I ;
Lazeyras, F ;
Foxall, D ;
Vallée, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :771-778
[8]   IN-VIVO QUANTIFICATION OF THE UNIDIRECTIONAL INFLUX CONSTANT FOR GD-DTPA DIFFUSION ACROSS THE MYOCARDIAL CAPILLARIES WITH MR-IMAGING [J].
LARSSON, HBW ;
STUBGAARD, M ;
SONDERGAARD, L ;
HENRIKSEN, O .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :433-440
[9]   Myocardial perfusion modeling using MRI [J].
Larsson, HBW ;
FritzHansen, T ;
Rostrup, E ;
Sondergaard, L ;
Ring, P ;
Henriksen, O .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :716-726
[10]   Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart [J].
Larsson, HBW ;
Rosenbaum, S ;
Fritz-Hansen, T .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :272-281