Cathodic stripping voltammetry of selenium(IV) at a silver disk electrode

被引:46
作者
Ishiyama, T [1 ]
Tanaka, T [1 ]
机构
[1] SCI UNIV TOKYO,FAC ENGN,SHINJUKU KU,TOKYO 162,JAPAN
关键词
D O I
10.1021/ac960446r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple, and reproducible method is described for the determination of selenium(IV) based on differential pulse cathodic stripping voltammetry. The optimized experimental conditions are as follows: selenium(IV)I ions in an acidic medium (0.06 M HCl-0.07 M HNO3) are electrodeposited on a rotating silver disk electrode as silver selenide at -0.4 V vs SCE for 30 min; the deposit is then cathodically stripped in another solution (2 M NaOH) at a scan rate of 50 mV s(-1) to -1.2 V vs SCE. The cathodic stripping results in only a single well-defined peak at about -0.95 V vs SCE. The calibration (peak height vs selenium concentration) graph is linear up to at least 40 ng mL(-1) of selenium(IV) and passes through the origin, with a relative standard deviation of 2.7% for 20 ng mL(-1) (n = 5). The detection limit (3 sigma) is 0.20 ng mL(-1). The possible interferences have been evaluated. Dissolved oxygen does not affect the peak height of selenium. The electrode can be used repeatedly at least 20 times with excellent reproducibility without further polishing. The proposed method is an improvement over the existing cathodic stripping techniques.
引用
收藏
页码:3789 / 3792
页数:4
相关论文
共 25 条
[1]   DETERMINATION OF SELENIUM, COPPER, LEAD AND CADMIUM IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE STRIPPING VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
HUGHES, HC .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :59-69
[2]   STRIPPING VOLTAMMETRIC DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS BY DIRECT CALIBRATION [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH ;
HUGHES, HC .
ANALYTICAL CHEMISTRY, 1983, 55 (13) :2076-2082
[3]   VOLTAMMETRIC DEPOSITION AND STRIPPING OF SELENIUM(IV) AT A ROTATING GOLD-DISK ELECTRODE IN 0.1M PERCHLORIC-ACID [J].
ANDREWS, RW ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1975, 47 (02) :294-299
[4]   PARAMETER EVALUATION FOR THE DETERMINATION OF SELENIUM BY CATHODIC STRIPPING VOLTAMMETRY AT THE HANGING MERCURY DROP ELECTRODE [J].
BALTENSPERGER, U ;
HERTZ, J .
ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) :49-56
[5]   VOLTAMMETRIC BEHAVIOR OF SELENIUM(IV) AT HANGING MERCURY DROP ELECTRODES IN ACETATE BUFFER [J].
CAMPANELLA, L ;
FERRI, T .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 165 (1-2) :241-249
[6]   A VOLTAMMETRIC STUDY OF THE ELECTRODEPOSITION CHEMISTRY OF THE CU+SE SYSTEM [J].
CARBONNELLE, P ;
LAMBERTS, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 340 (1-2) :53-71
[7]   IMPROVED METHOD FOR THE SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF SELENIUM AND TELLURIUM BY CATHODIC-STRIPPING [J].
EBHARDT, KB ;
UMLAND, F .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 310 (05) :406-409
[8]   DETERMINATION OF SELENIUM IN SOILS AND PLANTS BY DIFFERENTIAL PULSE CATHODIC-STRIPPING VOLTAMMETRY [J].
FORBES, S ;
BOUND, GP ;
WEST, TS .
TALANTA, 1979, 26 (06) :473-477
[9]   DETERMINATION OF SELENIUM AND TELLURIUM IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE [J].
HAMILTON, TW ;
ELLIS, J ;
FLORENCE, TM .
ANALYTICA CHIMICA ACTA, 1979, 110 (01) :87-94
[10]  
HENZE G, 1981, MIKROCHIM ACTA, V2, P343