Error estimates in novice and expert raters for the KT-1000 arthrometer

被引:49
作者
Berry, J
Kramer, K
Binkley, J
Binkley, GA
Stratford, P
Hunter, S
Brown, K
机构
[1] Wesley Woods Geriatr Hosp, Atlanta, GA USA
[2] Sartori Hosp, Cedar Falls, IA USA
[3] Appalachian Phys Therapy, Dahlonega, GA USA
[4] McMaster Univ, Dept Clin Epidemiol & Biostat, Hamilton, ON, Canada
[5] Clemson Sports Med & Rehabil, Clemson, SC USA
[6] Brenau Univ, Dept Occupat Therapy, Gainesville, GA USA
[7] N Georgia Coll, Phys Therapy Dept, Dahlonega, GA USA
关键词
standard error of measurement; reliability; testing;
D O I
10.2519/jospt.1999.29.1.49
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Single group repeated measures with multiple raters. Objectives: To determine the inter-rater reliability of KT-1000 measurements of novice and experienced raters and to provide error estimates for these raters. Background: The KT-1000 arthrometer is often used clinically to quantify anterior tibial displacement. Few data have been documented, however, about the relative reliability of KT-1000 measurements obtained by novice compared with experienced users. Methods and Measures: Two novice and two experienced KT-1000 users performed measurements on 29 knees of 25 patients after anterior cruciate ligament (ACL) reconstruction or with a diagnosis of ACL deficiency Measurements were performed at 131 N. Interrater and intertrial reliability coefficients (interclass correlation coefficient; [CI]) and the standard error of measurement were calculated for expert and novice raters. Results: The interrater [CC for novices was 0.65 and the interrater error was +/-3.52 mm (90% confidence interval [CI]). The interrater [CC for experts was 0.79 and the interrater error was +/-2.94 mm (90% CI). Conclusions: These results suggest that experience in using the KT-1000 is related to the interrater error of measurements and that training is an important consideration when using the KT-1000 arthrometer.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 18 条
[1]   PREOPERATIVE INSTRUMENTED TESTING OF ANTERIOR AND POSTERIOR KNEE LAXITY [J].
ANDERSON, AF ;
LIPSCOMB, AB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (03) :387-392
[2]  
ARMITAGE P, 1994, STAT METHODS MED RES, P221
[3]  
BALANTYNE BT, 1995, PHYS THER, V75, P898
[4]   INSTRUMENTED MEASUREMENT OF ANTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
MALCOM, LL ;
LOSSE, G ;
STONE, ML ;
SACHS, R ;
BURKS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (05) :720-726
[5]  
DANIEL DM, 1994, REFERENCE MAINTENANC
[6]  
DANIEL DM, 1990, KNEE LIGAMENTS STRUC
[7]   COMPARATIVE MEASUREMENTS OF ANTERIOR TIBIAL TRANSLATION USING THE KT-1000 KNEE ARTHROMETER WITH THE LEG IN NEUTRAL, INTERNAL-ROTATION, AND EXTERNAL ROTATION [J].
FIEBERT, I ;
GRESLEY, J ;
HOFFMAN, S ;
KUNKEL, K .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 19 (06) :331-334
[8]   RELIABILITY OF MEASURING ANTERIOR LAXITY OF THE KNEE-JOINT USING A KNEE LIGAMENT ARTHROMETER [J].
HANTEN, WP ;
PACE, MB .
PHYSICAL THERAPY, 1987, 67 (03) :357-359
[9]   KT-1000 ARTHROMETER - CONSCIOUS AND UNCONSCIOUS TEST-RESULTS USING 15, 20, AND 30 POUNDS OF FORCE [J].
HIGHGENBOTEN, CL ;
JACKSON, AW ;
JANSSON, KA ;
MESKE, NB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (04) :450-454
[10]   QUANTITATIVE-ANALYSIS OF THE MEASURING CAPABILITIES OF THE KT-1000 KNEE LIGAMENT ARTHROMETER [J].
KOWALK, DL ;
WOJTYS, EM ;
DISHER, J ;
LOUBERT, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (05) :744-747