Solid phase extraction (SPE) in two layers cartridge for simultaneous analysis of medium and highly polar pesticides in waters

被引:9
作者
Gerard, M [1 ]
Barthelemy, JP [1 ]
Copin, A [1 ]
机构
[1] Univ Gembloux, Fac Sci Agron, Unite Chim Analyt & Phytopharm, B-5030 Gembloux, Belgium
关键词
HPLC-DAD; GC-NPD; pesticides; waters; solid phase extraction;
D O I
10.1080/03067310108044364
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
HPLC-DAD and GC-NPD methods were developed to measure medium and highly polar pesticide concentrations in ground and surface waters. To analyse these pesticides in relation with the European Directives, a comparison of different "off-line" solid phase extraction sorbents was carried out. The use of a home-made (SPE) two layers poly(divinylbenzene-co-N-vinylpyrrolidone) - octadecyl-bonded silica (Oasis-C18) cartridge allows to analyse simultaneously medium and highly polar pesticides in natural waters, with quantification limits between 0.03 and 0.05 mug/l according to each pesticide. The recoveries on this sorbent vary between 90 and 105 % with R.S.D. below 7 % in MilliQ water and between 88 and 115 % with R.S.D. below 20 %, except for bentazone (26 %), in surface water.
引用
收藏
页码:281 / 294
页数:14
相关论文
共 25 条
[1]   Pesticide concentrations in Louros River and their fluxes into the marine environment [J].
Albanis, TA ;
Hela, DG .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1998, 70 (1-4) :105-120
[2]   Monitoring of priority pesticides and other organic pollutants in river water from Portugal by gas chromatography-mass spectrometry and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry [J].
Azevedo, DD ;
Lacorte, S ;
Vinhas, T ;
Viana, P ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) :13-26
[3]  
BEERNAERTS S, 1997, ESTIMATION PERTES PR
[4]   Separation of phenylurea pesticides by ion-interaction reversed-phase high-performance liquid chromatography - Diuron determination in lagoon water [J].
Gennaro, MC ;
Abrigo, C ;
Giacosa, D ;
Rigotti, L ;
Liberatori, A .
JOURNAL OF CHROMATOGRAPHY A, 1995, 718 (01) :81-88
[5]  
GERARD M, 1997, PREVISION POLLUTION
[6]  
HEINZ I, 1996, EC EFFICIENCY CALCUL
[7]   Analysis of pesticides in water with liquid chromatography atmospheric pressure chemical ionization mass spectrometry [J].
Hu, JY ;
Aizawa, T ;
Magara, Y .
WATER RESEARCH, 1999, 33 (02) :417-425
[8]   Evaluation of pesticide residues in water [J].
Jaskulké, E ;
Patty, L ;
Bruchet, A .
PESTICIDE CHEMISTRY AND BIOSCIENCE: THE FOOD-ENVIRONMENT CHALLENGE, 1999, (233) :368-385
[9]  
LEGUBE B, 1991, ANALUSIS, V19, pI15
[10]   Surface water pollution by herbicides from effluents of waste water treatment plants [J].
Nitschke, L ;
Schussler, W .
CHEMOSPHERE, 1998, 36 (01) :35-41