In this longitudinal study, we evaluated the sensitivities of dual-echo, conventional spin-echo (CSE), and rapid-acquisition relaxation-enhanced (RARE) scans for detecting the appearance of new lesions in multiple sclerosis (MS). Dual echo, CSE, and RARE scans were obtained on four occasions each separated by 28 days from five patients with relapsing-remitting MS using a 1.5-Tesla machine. A total of 44 nem lesions mere detected by the two sequences, Thirty-five lesions mere seen on both sequences, three only on CSE and six only on FSE. This study indicates that CSE may be substituted by RARE when monitoring short-term disease activity in MS. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:457 / 458
页数:2
相关论文
共 12 条
[1]  
Bastianello S, 1997, AM J NEURORADIOL, V18, P699
[2]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[3]   A MAGNETIZATION-TRANSFER IMAGING STUDY OF NORMAL-APPEARING WHITE-MATTER IN MULTIPLE-SCLEROSIS [J].
FILIPPI, M ;
CAMPI, A ;
DOUSSET, V ;
BARATTI, C ;
MARTINELLI, V ;
CANAL, N ;
SCOTTI, G ;
COMI, G .
NEUROLOGY, 1995, 45 (03) :478-482
[4]   MICROSCOPIC DISEASE IN NORMAL-APPEARING WHITE-MATTER ON CONVENTIONAL MR-IMAGES IN PATIENTS WITH MULTIPLE-SCLEROSIS - ASSESSMENT WITH MAGNETIZATION-TRANSFER MEASUREMENTS [J].
LOEVNER, LA ;
GROSSMAN, RI ;
COHEN, JA ;
LEXA, FJ ;
KESSLER, D ;
KOLSON, DL .
RADIOLOGY, 1995, 196 (02) :511-515
[5]   Defining the clinical course of multiple sclerosis: Results of an international survey [J].
Lublin, FD ;
Reingold, SC .
NEUROLOGY, 1996, 46 (04) :907-911
[6]   USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING LESIONS TO MONITOR DISEASE-ACTIVITY IN MULTIPLE-SCLEROSIS [J].
MCFARLAND, HF ;
FRANK, JA ;
ALBERT, PS ;
SMITH, ME ;
MARTIN, R ;
HARRIS, JO ;
PATRONAS, N ;
MALONI, H ;
MCFARLIN, DE .
ANNALS OF NEUROLOGY, 1992, 32 (06) :758-766
[7]   Guidelines for the use of magnetic resonance techniques in monitoring the treatment of multiple sclerosis [J].
Miller, DH ;
Albert, PS ;
Barkhof, F ;
Francis, G ;
Frank, JA ;
Hodgkinson, S ;
Lublin, FD ;
Paty, DW ;
Reingold, SC ;
Simon, J .
ANNALS OF NEUROLOGY, 1996, 39 (01) :6-16
[8]   MAGNETIC-RESONANCE-IMAGING IN MONITORING THE TREATMENT OF MULTIPLE-SCLEROSIS - CONCERTED ACTION GUIDELINES [J].
MILLER, DH ;
BARKHOF, F ;
BERRY, I ;
KAPPOS, L ;
SCOTTI, G ;
THOMPSON, AJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1991, 54 (08) :683-688
[9]   MAGNETIC-RESONANCE-IMAGING IN MONITORING THE TREATMENT OF MULTIPLE-SCLEROSIS PATIENTS - STATISTICAL POWER OF PARALLEL-GROUPS AND CROSSOVER DESIGNS [J].
NAUTA, JJP ;
THOMPSON, AJ ;
BARKHOF, F ;
MILLER, DH .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 1994, 122 (01) :6-14
[10]   A COMPARISON BETWEEN FAST AND CONVENTIONAL SPIN-ECHO IN THE DETECTION OF MULTIPLE-SCLEROSIS LESIONS [J].
THORPE, JW ;
HALPIN, SF ;
MACMANUS, DG ;
BARKER, GJ ;
KENDALL, BE ;
MILLER, DH .
NEURORADIOLOGY, 1994, 36 (05) :388-392