The effect of background structure on the detection of low contrast objects in mammography

被引:37
作者
Kotre, CJ [1 ]
机构
[1] Newcastle Gen Hosp, Dept Reg Med Phys, Newcastle Upon Tyne NE4 6BE, Tyne & Wear, England
关键词
D O I
10.1259/bjr.71.851.10434911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The visual task of mammographic interpretation is considered in terms of the detection of a signal in the presence of noise, where the noise is taken to include a structure noise contribution from those areas of the imaged breast which do not contain the signal. The structure noise in a variety of typical mammographic parenchymal patterns was quantified and related to the area under observation using a statistical analysis of digitized image samples. Images of an anthropomorphic phantom were also analysed to establish it as a suitable test background for a series of contrast detail detection experiments. These experiments were performed with and without a structured background over a wide range of film dose, but at a fixed average film optical density. The presence of structure noise was found to reduce the detectability of low contrast objects, the effect becoming progressively smaller as the object size is reduced. Where the structured background was used, even large changes in dose to the film were found to produce little change in the overall contrast detail result except at the smallest detail diameters. These results are discussed in relation to existing theories of visual perception. It is suggested that the correlation between patient dose and cancer detection rate may be poorer than previously thought, as the detection task for objects larger than approximately 1 mm in diameter is dominated by the structure noise of the background parenchymal pattern rather than quantum noise.
引用
收藏
页码:1162 / 1167
页数:6
相关论文
共 14 条
[1]
Bijkerk K.R., 1993, RADIOLOGY, V185, P395
[2]
COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]
Blanks R G, 1996, J Med Screen, V3, P82
[4]
Blanks R G, 1996, J Med Screen, V3, P79
[5]
DEVELOPMENT OF AN ANTHROPOMORPHIC BREAST PHANTOM [J].
CALDWELL, CB ;
YAFFE, MJ .
MEDICAL PHYSICS, 1990, 17 (02) :273-280
[6]
QUANTITATIVE RELATION BETWEEN DETECTABILITY AND NOISE POWER [J].
CHESTERS, MS ;
HAY, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (10) :1113-1125
[7]
ANALYSIS OF VARIATIONS IN CONTRAST-DETAIL EXPERIMENTS [J].
COHEN, G ;
MCDANIEL, DL ;
WAGNER, LK .
MEDICAL PHYSICS, 1984, 11 (04) :469-473
[8]
COWAN AR, 1997, PHYS MED BIOL, V42, P1533
[9]
HAY GA, 1976, THRESHOLD MECHANISMS, P208
[10]
*I PHYS SCI MED, 1994, 59 IPEMB I PHYS SCI