Measurement of radiation damage on a silica aerogel Cherenkov radiator

被引:8
作者
Sahu, SK
Wang, MZ
Suda, R
Enomoto, R
Peng, KC
Wang, CH
Adachi, I
Amami, M
Chang, YH
Guo, RS
Hayashi, K
Iijima, T
Sumiyoshi, T
Yoshida, Y
机构
[1] KEK NAT LAB HIGH ENERGY PHYS,IBARAKI,OSAKA 395,JAPAN
[2] NATL TAIWAN UNIV,TAIPEI 10764,TAIWAN
[3] NATL KAOHSIUNG NORMAL UNIV,KAOHSIUNG,TAIWAN
[4] TOKYO METROPOLITAN UNIV,TOKYO 19203,JAPAN
[5] NATL LIEN HO COLL TECH & COMMERCE,MIAOLI,TAIWAN
[6] SAGA UNIV,SAGA 840,JAPAN
[7] NATL CENT UNIV,CHUNGLI 32054,TAIWAN
[8] TOHO UNIV,CHIBA 274,JAPAN
关键词
D O I
10.1016/S0168-9002(96)00768-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We measured the radiation damage on silica aerogel Cherenkov radiators originally developed for the B-factory experiment at KEK. The refractive index of the aerogel samples ranged from 1.012 to 1.028. The samples were irradiated up to 9.8 Mrad of equivalent dose. Measurements of transmittance and refractive index were carried out and these samples were found to be radiation hard. Deteriorations in transparency and changes of refractive index were observed to be less than 1.3% and 0.001 at 90% confidence lever, respectively. Prospects of using aerogels under high-radiation environment are discussed.
引用
收藏
页码:441 / 446
页数:6
相关论文
共 23 条
  • [1] STUDY OF A THRESHOLD CHERENKOV COUNTER BASED ON SILICA AEROGELS WITH LOW REFRACTIVE-INDEXES
    ADACHI, I
    SUMIYOSHI, T
    HAYASHI, K
    IIDA, N
    ENOMOTO, R
    TSUKADA, K
    SUDA, R
    MATSUMOTO, S
    NATORI, K
    YOKOYAMA, M
    YOKOGAWA, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3) : 390 - 398
  • [2] A SILICA AEROGEL COUNTER FOR LARGE-ACCEPTANCE HADRON DETECTION
    ARNAULT, C
    HEUSSE, P
    BARBERIS, PL
    DOSSELLI, U
    BUCKHARDT, W
    MONTANET, F
    BASSOMPIERRE, G
    COIGNET, G
    SCHNEEGANS, M
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1980, 177 (2-3): : 337 - 346
  • [3] BaBar, SLACR95457
  • [4] *BELL COLL, KEK P 951
  • [5] *BELL COLL, KEK942
  • [6] THE TASSO GAS AND AEROGEL CHERENKOV COUNTERS
    BURKHARDT, H
    KOEHLER, P
    RIETHMULLER, R
    WIIK, BH
    FOHRMANN, R
    FRANZKE, J
    KRASEMANN, H
    MASCHUW, R
    POELZ, G
    REICHARDT, J
    RINGEL, J
    ROMER, O
    RUSCH, R
    SCHMUSER, P
    VANSTAA, R
    FREEMAN, J
    LECOMTE, P
    MEYER, T
    WU, SL
    ZOBERNIG, G
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1981, 184 (2-3): : 319 - 331
  • [7] TESTS OF AN 18 MODULE SILICA AEROGEL CHERENKOV DETECTOR TO BE USED IN THE EUROPEAN HYBRID SPECTROMETER
    CARLSON, PJ
    JOHANSSON, KE
    KESTEMAN, J
    NORRBY, J
    PINGOT, O
    TAVERNIER, S
    VANLANCKER, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 192 (2-3): : 209 - 216
  • [8] CP NON-CONSERVATION IN CASCADE DECAYS OF B-MESONS
    CARTER, AB
    SANDA, AI
    [J]. PHYSICAL REVIEW LETTERS, 1980, 45 (12) : 952 - 954
  • [9] SILICA AEROGEL CHERENKOV COUNTER IN A MISSING-MASS EXPERIMENT K-D-]K++X AT 1.4-GEV-C
    DEBRION, JP
    CAILLET, A
    CHEZE, JB
    DERRE, J
    MAREL, G
    PAULI, E
    PIGOT, C
    VRANA, G
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (01): : 61 - 65
  • [10] ENGELMANN JJ, 1990, ASTRON ASTROPHYS, V233, P96