A chemical sensor array based system for protecting wastewater treatment plants

被引:46
作者
Bourgeois, W
Gardey, G
Servieres, M
Stuetz, RM
机构
[1] Cranfield Univ, Sch Water Sci, Cranfield MK43 0AL, Beds, England
[2] Ecole Cent Nantes, F-44321 Nantes, France
基金
英国工程与自然科学研究理事会;
关键词
conducting polymer; on-line monitoring; wastewater; early warning; pollution;
D O I
10.1016/S0925-4005(03)00074-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemical sensor array (consisting of eight conducting polymer (CP) sensors) was used to continuously monitor for sudden changes in the quality of wastewater over a 12-month period. The headspace gas generated from a sparged liquid sample within a temperature controlled flow-cell was directly transferred to the sensor chamber for analysis. Results from. the field study at a wastewater treatment plant (using a fully automated system) provided high resolution profiles and showed the detection of accidental and simulated pollution events. A model was developed for the detection and identification of sudden changes in the sensor responses, and was successfully tested using large datasets acquired over several months. This simple data mining approach showed a great sensitivity and flexibility, independent of long-term drift effects, diurnal variations and changes in temperature and humidity levels. The findings demonstrate that a chemical sensor array can be operated under harsh environmental conditions and act as an upset early warning device for the detection and identification of wastewater treatment process failure. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 10 条
[1]   Development of a sensor array based measurement system for continuous monitoring of water and wastewater [J].
Bourgeois, W ;
Hogben, P ;
Pike, A ;
Stuetz, RM .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (03) :312-319
[2]   Measuring wastewater quality using a sensor array: prospects for real-time monitoring [J].
Bourgeois, W ;
Stuetz, RM .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (12) :107-112
[3]  
BOURGEOIS W, 2001, J CHEM TECH BIOTECHN, V76, P1
[4]   Needs and uses of continuous monitoring equipment for waste water treatment. Standardization y/n? [J].
Cecile, JL .
MONITORING OF WATER QUALITY: THE CONTRIBUTION OF ADVANCED TECHNOLOGIES, 1998, :237-244
[5]   The electronic nose as a rapid sensor for volatile compounds in treated domestic wastewater [J].
Dewettinck, T ;
Van Hege, K ;
Verstraete, W .
WATER RESEARCH, 2001, 35 (10) :2475-2483
[6]   Characterisation of wastewater using an electronic nose [J].
Stuetz, RM ;
Fenner, RA ;
Engin, G .
WATER RESEARCH, 1999, 33 (02) :442-452
[7]  
Stuetz RM, 1999, J CHEM TECHNOL BIOT, V74, P1069, DOI 10.1002/(SICI)1097-4660(199911)74:11<1069::AID-JCTB154>3.0.CO
[8]  
2-2
[9]   Wastewater quality monitoring [J].
Thomas, O ;
Theraulaz, F ;
Cerda, V ;
Constant, D ;
Quevauviller, P .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (07) :419-424
[10]   Sensors for waste water: Many needs but financial and technical limitations [J].
Wacheux, H .
MONITORING OF WATER QUALITY: THE CONTRIBUTION OF ADVANCED TECHNOLOGIES, 1998, :229-235