A purity monitoring system for liquid argon calorimeters

被引:9
作者
Adams, M
Buchholz, P
Dahlhoff, A
Feiden, D
Gärtner, V
Grams, M
Haarmann, M
Hergesell, A
Hölldorfer, F
Ielapi, G
Jakobs, K
Jung, T
Köpke, L
Kuhnert, E
Meder, D
Schäfer, U
Schmidt, A
Schué, Y
Schwarz, C
Walkowiak, W
Weber, D
Wilke, D
Zeitnitz, C [1 ]
机构
[1] Univ Mainz, Inst Phys, D-55099 Mainz, Germany
[2] Univ Siegen, Fachbereich Phys, D-57068 Siegen, Germany
[3] Univ Freiburg, Inst Phys, D-79104 Freiburg, Germany
关键词
liquid argon; electron attachment; calorimetry;
D O I
10.1016/j.nima.2005.03.117
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For liquid argon calorimeters electronegative impurities dissolved in the medium degrade the detector response and deteriorate the energy resolution, especially at high energies. A concept for a purity monitoring system for liquid argon calorimeters has been developed and is presented here. Special combined monitors of Am-241- and (207) Bi-cells are used to monitor the concentration of impurities. The working principle as well as results from test measurements are discussed. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:613 / 623
页数:11
相关论文
共 8 条
[1]   EFFECT OF AN ELECTRIC-FIELD ON ELECTRON-ATTACHMENT TO SF6, N2O, AND O-2 IN LIQUID ARGON AND XENON [J].
BAKALE, G ;
SOWADA, U ;
SCHMIDT, WF .
JOURNAL OF PHYSICAL CHEMISTRY, 1976, 80 (23) :2556-2559
[2]   ELECTRON LIFETIME DETECTOR FOR LIQUID ARGON [J].
CARUGNO, G ;
DAINESE, B ;
PIETROPAOLO, F ;
PTOHOS, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (03) :580-584
[3]   MARS-2 - A CURRENT SENSITIVE LIQUID ARGON CALORIMETER [J].
CERRI, C ;
DENISOV, SP ;
GENNARO, G ;
KRASNOKUTSKY, RN ;
LEBEDEV, AA ;
MEDVED, SA ;
MIKHAILOV, VS ;
NAUMOV, NI ;
RAGADINI, M ;
RASUVAEV, EA ;
SERGIAMPIETRI, F ;
SHUVALOV, RS ;
SPANDRE, G ;
STOYANOVA, DA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) :227-236
[4]   SPEED AND NOISE LIMITS IN IONIZATION-CHAMBER CALORIMETERS [J].
RADEKA, V ;
RESCIA, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 265 (1-2) :228-242
[5]   STATISTICS OF CHARGE COLLECTION IN LIQUID ARGON AND LIQUID XENON [J].
THOMAS, J ;
IMEL, DA ;
BILLER, S .
PHYSICAL REVIEW A, 1988, 38 (11) :5793-5800
[6]   RECOMBINATION OF ELECTRON-ION PAIRS IN LIQUID ARGON AND LIQUID XENON [J].
THOMAS, J ;
IMEL, DA .
PHYSICAL REVIEW A, 1987, 36 (02) :614-616
[8]  
WALKOWIAK W, 1998, THESIS MAINZ