Intracardiac echocardiography: In vitro and in vivo validation for right ventricular volume and function

被引:13
作者
dePrada, JAV
Chen, MH
Guerrero, JL
Padial, LR
Jiang, L
Schwammenthal, E
Sagie, A
Weyman, AE
Levine, RA
Chen, CG
机构
[1] HARTFORD HOSP, DIV CARDIOL, HARTFORD, CT 06102 USA
[2] HARVARD UNIV, MASSACHUSETTS GEN HOSP,SCH MED,DEPT MED, CARDIAC ULTRASOUND LAB, BOSTON, MA USA
[3] UNIV CONNECTICUT, SCH MED, HARTFORD, CT 06112 USA
关键词
D O I
10.1016/S0002-8703(96)90361-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the feasibility and accuracy of intracardiac ultrasonography (ICUS) for the measurement of right ventricular (RV) volumes and function, a 10 MHz ICUS catheter was used in an in vitro and in vivo model. In the in vitro study, 16 sheep hearts were imaged. Sequential cross-sectional images from RV apex to base were recorded during a calibrated pullback. Volumes were calculated by applying Simpson's algorithm. ICUS-obtained volumes correlated well with actual volumes (standard error of estimate [SEE] = 2.3 ml, r = 0.98). For the in vivo study, a beating-heart canine model was used (31 hemodynamic stages in six dogs). Actual volumes were measured by an intracavitary balloon connected to an external column. Sequential cross-sectional images were recorded during the ICUS catheter pullback from apex to base of the RV, and volumes calculated by Simpson's algorithm. Good correlations were observed between ICUS and actual values for diastolic (SEE = 4.1 ml, r = 0.97), systolic (SEE = 3.4 ml, r = 0.96), and ejection fraction (SEE = 3.1%, r = 0.87) values. This new technique can accurately quantitate RV volumes, can function both in vitro and in vivo, and has the potential for increasing applications to questions of clinical and research interest.
引用
收藏
页码:320 / 328
页数:9
相关论文
共 29 条
[11]  
JIANG L, 1993, PRINCIPLES PRACTICE, P901
[12]   ASSESSMENT OF RIGHT VENTRICULAR-FUNCTION USING TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
KAUL, S ;
TEI, C ;
HOPKINS, JM ;
SHAH, PM .
AMERICAN HEART JOURNAL, 1984, 107 (03) :526-531
[13]  
LANGE PE, 1978, EUR J CARDIOL, V8, P477
[14]   ECHOCARDIOGRAPHIC MEASUREMENT OF RIGHT VENTRICULAR VOLUME [J].
LEVINE, RA ;
GIBSON, TC ;
ARETZ, T ;
GILLAM, LD ;
GUYER, DE ;
KING, ME ;
WEYMAN, AE .
CIRCULATION, 1984, 69 (03) :497-505
[15]   DISCORDANCE IN DEGREE OF RIGHT AND LEFT-VENTRICULAR DILATION IN PATIENTS WITH DILATED CARDIOMYOPATHY - RECOGNITION AND CLINICAL IMPLICATIONS [J].
LEWIS, JF ;
WEBBER, JD ;
SUTTON, LL ;
CHESONI, S ;
CURRY, CL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (03) :649-654
[16]   MEASUREMENT ACCURACY OF CARDIAC-OUTPUT IN HUMANS - INDICATOR-DILUTION TECHNIQUE VERSUS GEOMETRIC ANALYSIS BY ULTRAFAST COMPUTED-TOMOGRAPHY [J].
LUDMAN, PF ;
COATS, AJS ;
POOLEWILSON, PA ;
REES, RSO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (06) :1482-1489
[17]  
MATSUMURA M, 1993, CIRCULATION, V88, P658
[18]   RIGHT VENTRICULAR EJECTION FRACTION AND VOLUMES AFTER MUSTARD REPAIR - CORRELATION OF TWO-DIMENSIONAL ECHOCARDIOGRAMS AND CINEANGIOGRAMS [J].
NINOMIYA, K ;
DUNCAN, WJ ;
COOK, DH ;
OLLEY, PM ;
ROWE, RD .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (02) :317-324
[19]  
PADIAL LR, 1994, J AM SOC ECHOCARDI S, V7, pS44
[20]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ESTIMATION OF RIGHT VENTRICULAR EJECTION FRACTION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
PANIDIS, IP ;
REN, JF ;
KOTLER, MN ;
MINTZ, G ;
ISKANDRIAN, A ;
ROSS, J ;
KANE, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (05) :911-918