Spatially-resolved analysis of solids by laser ablation-inductively coupled plasma-mass spectrometry: trace elemental quantification without matrix-matched solid standards

被引:36
作者
Aeschliman, DB [1 ]
Bajic, SJ [1 ]
Baldwin, DP [1 ]
Houk, RS [1 ]
机构
[1] Iowa State Univ, Dept Chem, Ames Lab, US Dept Energy, Ames, IA 50011 USA
关键词
D O I
10.1039/b205683f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A two-point calibration method for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is assessed. Desolvated particles from a Teflon microconcentric nebulizer and particles ablated from a localized position on a solid sample are mixed and introduced simultaneously into an ICP magnetic sector mass spectrometer. Analyte signals from the solution are compared with those from the ablated solid for calibration. Matrix-matched or pelletized solid standards and prior knowledge of sample composition are not required for calibration. The transport of sample particulates from the ablation cell is measured online with a piezoelectric microbalance to provide signal normalization. The relative accuracy of the quantitative analysis of NIST SRM 612 glass and NIST SRM 1264a steel is 3% to 12%, respectively, except for the elements Pb and Bi in steel. These two elements are distributed heterogeneously and are probably subject to fractionation. The use of helium instead of argon as transport gas reduced fractionation but did not eliminate it. The analyte concentrations were approximately 15-51 ppm in NIST SRM 612 glass and 9-2500 ppm in NIST SRM 1264a steel.
引用
收藏
页码:872 / 877
页数:6
相关论文
共 30 条
[1]   The use of Pt guard electrode in inductively coupled plasma sector field mass spectrometry: advantages and limitations [J].
Appelblad, PK ;
Rodushkin, I ;
Baxter, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :359-364
[2]   AEROSOL MASS MEASUREMENT AND SOLUTION STANDARD ADDITIONS FOR QUANTITATION IN LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
BALDWIN, DP ;
ZAMZOW, DS ;
DSILVA, AP .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1911-1917
[3]  
Becker JS, 1996, FRESEN J ANAL CHEM, V355, P626
[4]   Determination of trace elements in high-purity platinum by laser ablation inductively coupled plasma mass spectrometry using solution calibration [J].
Becker, JS ;
Pickhardt, C ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) :603-606
[5]   Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects [J].
Durrant, SF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1385-1403
[6]   Deposition and element fractionation processes during atmospheric pressure laser sampling for analysis by ICP-MS [J].
Eggins, SM ;
Kinsley, LPJ ;
Shelley, JMG .
APPLIED SURFACE SCIENCE, 1998, 127 :278-286
[7]   Calibration of laser-ablation ICP-MS. Can we use synthetic standards with pneumatic nebulization? [J].
Falk, HF ;
Hattendorf, B ;
Krengel-Rothensee, K ;
Wieberneit, N ;
Dannen, SL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (05) :468-472
[8]   Laser ablation ICP-MS analyses of tree-ring profiles in pine and birch from N Norway and NW Russia - a reliable record of the pollution history of the area? [J].
GarbeSchonberg, CD ;
Reimann, C ;
Pavlov, VA .
ENVIRONMENTAL GEOLOGY, 1997, 32 (01) :9-16