Anaphylaxis to gadobenate dimeglumine (Multihance®):: A case report

被引:31
作者
Kalogeromitros, Dimitrios C.
Makris, Michael P.
Aggelides, Xenophon S.
Spanoudaki, Nektaria
Gregoriou, Stamatios G.
Avgerinou, Georgia
Rigopoulos, Dimitrios G.
机构
[1] Univ Athens, Attikon Hosp, Allergol Unit, GR-12462 Xaidari, Greece
[2] Andreas Sygros Hosp, Dermatol & Venereal Clin 1, Athens, Greece
关键词
gadobenate dimeglumine; skin testing; anaphylaxis; adverse reaction; Multihance((R));
D O I
10.1159/000103227
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Gadolinium chelates are relatively safe contrast media used in MRI. Immediate severe adverse effects are exceptionally rare and mostly concern mild anaphylactoid reactions. We report a case of anaphylaxis to gadobenate dimeglumine (Gd-BOPTA, Multihance((R))), a gadolinium-based contrast agent. Methods: A 32-year-old female patient with a personal history of multiple sclerosis, while undergoing an MRI scan, developed bronchospasm and acute urticaria with diffuse giant pruritic plaques in the first minute of Gd-BOPTA infusion. The procedure was cancelled and acute treatment of the reaction took place. The patient reported 2 additional MRI scans with definite use of unknown contrast media in the past 2 years without any adverse effect. Blood samples were obtained 2 and 48 h after the reaction for measurement of serum tryptase concentration (Pharmacia Diagnostics, Uppsala, Sweden). Skin prick tests and intradermal tests were performed using 1: 1,000, 1: 100 and 1: 10 dilution of the offending agent and alternative gadolinium-based agents [gadodiamide (Omniscan((R))) and gadoteric acid (Dotarem((R)))]. A group of 10 nonatopic individuals who under went the same skin testing comprised the control group. Results: Tryptase concentration was highly elevated 2 h after the reaction (21 mu g/l) compared with that at 48 h (3 mu g/l). Skin prick tests in our patient were all negative, while intradermal testing with 0.03 ml of 1: 100 and 1: 10 preparations of Multihance showed a definite positive wheal-and-flare reaction. Skin tests to the alternative agents showed no response. In the control group, all performed tests were negative. Conclusion: We report the first case of an allergic reaction to gadobenate dimeglumine. Besides, skin testing seems to be a precious diagnostic tool which, if positive, strongly suggests a mast cell-mediated underlying mechanism. Copyright (c) 2007 S. Karger AG, Basel.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 17 条
[1]   Guidelines for performing skin tests with drugs in the investigation of cutaneous adverse drug reactions [J].
Barbaud, A ;
Gonçalo, M ;
Bruynzeel, D ;
Bircher, A .
CONTACT DERMATITIS, 2001, 45 (06) :321-328
[2]   Management of hypersensitivity reactions to iodinated contrast media [J].
Brockow, K ;
Christiansen, C ;
Kanny, G ;
Clément, O ;
Barbaud, A ;
Bircher, A ;
DeWachter, P ;
Guéant, JL ;
Guéant, RMR ;
Mouton-Faivre, C ;
Ring, J ;
Romano, A ;
Sainte-Laudy, J ;
Demoly, P ;
Pichler, WJ .
ALLERGY, 2005, 60 (02) :150-158
[3]  
Brockow K, 2002, ALLERGY, V57, P45
[4]   Endovascular aortic aneurysm repair in patients with renal dysfunction or severe contrast allergy: Utility of imaging modalities without iodinated contrast [J].
Bush, RL ;
Lin, PH ;
Bianco, CC ;
Lumsden, AB ;
Gunnoud, AB ;
Terramani, TT ;
Brinkman, WT ;
Martin, LG ;
Weiss, VJ .
ANNALS OF VASCULAR SURGERY, 2002, 16 (05) :537-544
[5]   Allergy and contrast media [J].
Dewachter, P ;
Mouton-Faivre, C ;
Felden, F .
ALLERGY, 2001, 56 (03) :250-251
[6]   Safety assessment of gadobenate dimeglumine (MultiHance®):: Extended clinical experience from phase I studies to post-marketing surveillance [J].
Kirchin, MA ;
Pirovano, G ;
Venetianer, C ;
Spinazzi, A .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :281-294
[7]  
Kirchin Miles A, 2003, Top Magn Reson Imaging, V14, P426, DOI 10.1097/00002142-200310000-00007
[8]   Diagnosis of iodinated contrast media hypersensitivity: results of a 6-year period [J].
Kvedariene, V. ;
Martins, P. ;
Rouanet, L. ;
Demoly, P. .
CLINICAL AND EXPERIMENTAL ALLERGY, 2006, 36 (08) :1072-1077
[9]   Immediate reactions to contrast media: Mediator release and value of diagnostic testing [J].
Laroche, D .
TOXICOLOGY, 2005, 209 (02) :193-194
[10]   Mechanisms of severe, immediate reactions to iodinated contrast material [J].
Laroche, D ;
Aimone-Gastin, I ;
Dubois, F ;
Huet, H ;
Gérard, P ;
Vergnaud, MC ;
Mouton-Faivre, C ;
Guéant, JL ;
Laxenaire, MC ;
Bricard, H .
RADIOLOGY, 1998, 209 (01) :183-190