Field study on occupants' thermal comfort and residential thermal environment in a hot-humid climate of China

被引:165
作者
Han, Jie
Zhang, Guoqiang [1 ]
Zhang, Quan
Zhang, Jinwen
Liu, Jianlong
Tian, Liwei
Zheng, Cong
Hao, Junhong
Lin, Jianping
Liu, Yanhui
Moschandreas, Demetrios J.
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] China Architecture Design & Res Grp, Beijing 100044, Peoples R China
[3] IIT, Chicago, IL 60616 USA
基金
中国国家自然科学基金;
关键词
field study; residential thermal environment; occupant comfort; hot-humid climates;
D O I
10.1016/j.buildenv.2006.06.028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper discusses thermal comfort inside residences of three cities in the hot-humid climate of central southern China. Only a few thermal comfort studies have been performed in hot-humid climates and none in Central Southern China. Field sampling took place in the summers of 2003 and 2004 by obtaining 110 responses to a survey questionnaire and measuring environmental comfort variables in three rooms in each of 26 residences. The objectives are to measure and characterize occupant thermal perceptions in residences, compare observed and predicted percent of dissatisfied and discern differences between this study and similar studies performed in different climate zones. Average clothing insulation for seated subjects was 0.54 clo with 0.15 clo of chairs. Only 48.2% of the measured variables are within the ASHRAE Standard 55-1992 summer comfort zone, but approximately 87.3% of the occupants perceived their thermal conditions acceptable, for subjects adapt to prevailing conditions. The operative temperature denoting the thermal environment accepted by 90% of occupants is 22.0-25.9 degrees. In the ASHRAE seven-point sensation scale, thermal neutral temperature occurs at 28.6 degrees. Preferred temperature, mean temperature requested by respondents, is 22.8 degrees. Results of this study can be used to design low energy consumption systems for occupant thermal comfort in central southern China. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4043 / 4050
页数:8
相关论文
共 18 条
  • [1] [Anonymous], HV AC
  • [2] *ASHRAE, 1992, 551992 ASHRAE
  • [3] BENTON CC, 1990, ASHRAE TRAN, V96, P623
  • [4] Thermal comfort and behavioural strategies in office buildings located in a hot-arid climate
    Cena, K
    de Dear, R
    [J]. JOURNAL OF THERMAL BIOLOGY, 2001, 26 (4-5) : 409 - 414
  • [5] CENA K, 1994, THERMAL COMFORT PAST, P73
  • [6] de Dear R.J., 1994, ASHRAE T, V100, P457
  • [7] Dedear R, 1985, ASHRAE Transactions, V91, P452
  • [8] DONNINI G, 1996, ASHRAE T, V103, P465
  • [9] Fountain ME, 1996, ASHRAE J, V38, P39
  • [10] Howell W.C., 1981, ASHRAE Transactions, V87, P609