A Smartphone Client-Server Teleradiology System for Primary Diagnosis of Acute Stroke

被引:63
作者
Mitchell, J. Ross [1 ,2 ,3 ]
Sharma, Pranshu [1 ]
Modi, Jayesh [1 ]
Simpson, Mark [1 ]
Thomas, Monroe [3 ]
Hill, Michael D. [2 ]
Goyal, Mayank [2 ]
机构
[1] Univ Calgary, Imaging Informat Lab, Dept Radiol, Calgary, AB T2N 4N1, Canada
[2] Dept Clin Neurosci, Calgary, AB, Canada
[3] Calgary Sci Inc, Calgary, AB, Canada
关键词
Acute stroke; teleradiology; computed tomography; mhealth; mobile phone; COMPUTED-TOMOGRAPHY; CT; RELIABILITY; IMAGES; BRAIN; SCORE; VISUALIZATION; CONSULTATION; DEVICES; EXTENT;
D O I
10.2196/jmir.1732
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Recent advances in the treatment of acute ischemic stroke have made rapid acquisition, visualization, and interpretation of images a key factor for positive patient outcomes. We have developed a new teleradiology system based on a client-server architecture that enables rapid access to interactive advanced 2-D and 3-D visualization on a current generation smartphone device (Apple iPhone or iPod Touch, or an Android phone) without requiring patient image data to be stored on the device. Instead, a server loads and renders the patient images, then transmits a rendered frame to the remote device. Objective: Our objective was to determine if a new smartphone client-server teleradiology system is capable of providing accuracies and interpretation times sufficient for diagnosis of acute stroke. Methods: This was a retrospective study. We obtained 120 recent consecutive noncontrast computed tomography (NCCT) brain scans and 70 computed tomography angiogram (CTA) head scans from the Calgary Stroke Program database. Scans were read by two neuroradiologists, one on a medical diagnostic workstation and an iPod or iPhone (hereafter referred to as an iOS device) and the other only on an iOS device. NCCT brain scans were evaluated for early signs of infarction, which includes early parenchymal ischemic changes and dense vessel sign, and to exclude acute intraparenchymal hemorrhage and stroke mimics. CTA brain scans were evaluated for any intracranial vessel occlusion. The interpretations made on an iOS device were compared with those made at a workstation. The total interpretation times were recorded for both platforms. Interrater agreement was assessed. True positives, true negatives, false positives, and false negatives were obtained, and sensitivity, specificity, and accuracy of detecting the abnormalities on the iOS device were computed. Results: The sensitivity, specificity, and accuracy of detecting intraparenchymal hemorrhage were 100% using the iOS device with a perfect interrater agreement (kappa = 1). The sensitivity, specificity, and accuracy of detecting acute parenchymal ischemic change were 94.1%, 100%, and 98.09% respectively for reader 1 and 97.05%, 100%, and 99.04% for reader 2 with nearly perfect interrater agreement (kappa = .8). The sensitivity, specificity, and accuracy of detecting dense vessel sign were 100%, 95.4%, and 96.19% respectively for reader 1 and 72.2%, 100%, and 95.23% for reader 2 using the iOS device with a good interrater agreement (kappa = .69). The sensitivity, specificity, and accuracy of detecting vessel occlusion on CT angiography scans were 94.4%, 100%, and 98.46% respectively for both readers using the iOS device, with perfect interrater agreement (kappa = 1). No significant difference (P < .05) was noted in the interpretation time between the workstation and iOS device. Conclusion: The smartphone client-server teleradiology system appears promising and may have the potential to allow urgent management decisions in acute stroke. However, this study was retrospective, involved relatively few patient studies, and only two readers. Generalizing conclusions about its clinical utility, especially in other diagnostic use cases, should not be made until additional studies are performed.
引用
收藏
页数:12
相关论文
共 22 条
  • [1] Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapy
    Barber, PA
    Demchuk, AM
    Zhang, JJ
    Buchan, AM
    [J]. LANCET, 2000, 355 (9216) : 1670 - 1674
  • [2] *CAN ASS RAD, 2008, CAR STAND IRR COMPR
  • [3] Interobserver variation of ASPECTS in real time
    Coutts, SB
    Demchuk, AM
    Barber, PA
    Hu, WY
    Simon, JE
    Buchan, AM
    Hill, MD
    [J]. STROKE, 2004, 35 (05) : E103 - E105
  • [4] Importance of early ischemic computed tomography changes using ASPECTS in NINDS rtPA stroke study
    Demchuk, AM
    Hill, MD
    Barber, PA
    Silver, B
    Patel, SC
    Levine, SR
    [J]. STROKE, 2005, 36 (10) : 2110 - 2115
  • [5] Extent of early ischemic changes on computed tomography (CT) before thrombolysis - Prognostic value of the Alberta Stroke Program Early CT Score in ECASS II
    Dzialowski, I
    Hill, MD
    Coutts, SB
    Demchuk, AM
    Kent, DM
    Wunderlich, O
    von Kummer, R
    [J]. STROKE, 2006, 37 (04) : 973 - 978
  • [6] CT VISUALIZATION OF INTRACRANIAL ARTERIAL THROMBOEMBOLISM
    GACS, G
    FOX, AJ
    BARNETT, HJM
    VINUELA, F
    [J]. STROKE, 1983, 14 (05) : 756 - 762
  • [7] Comparison of MRI and CT for detection of acute intracerebral hemorrhage
    Kidwell, CS
    Chalela, JA
    Saver, JL
    Starkman, S
    Hill, MD
    Demchuk, AM
    Butman, JA
    Patronas, N
    Alger, JR
    Latour, LL
    Luby, ML
    Baird, AE
    Leary, MC
    Tremwel, M
    Ovbiagele, B
    Fredieu, A
    Suzuki, S
    Villablanca, JP
    Davis, S
    Dunn, B
    Todd, JW
    Ezzeddine, MA
    Haymore, J
    Lynch, JK
    Davis, U
    Warach, S
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (15): : 1823 - 1830
  • [8] PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link
    Kim, Dong Keun
    Yoo, Sun K.
    Park, Jeong Jin
    Kim, Sun Ho
    [J]. JOURNAL OF DIGITAL IMAGING, 2007, 20 (02) : 131 - 139
  • [9] Technologies for image distribution in hospitals
    Kotter, E
    Baumann, T
    Jäger, D
    Langer, M
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (06) : 1270 - 1279
  • [10] Validation of computed tomographic middle cerebral artery "Dot" sign - An angiographic correlation study
    Leary, MC
    Kidwell, CS
    Villablanca, JP
    Starkman, S
    Jahan, R
    Duckwiler, GR
    Gobin, YP
    Sykes, S
    Gough, KJ
    Ferguson, K
    Llanes, JN
    Masamed, R
    Tremwel, M
    Ovbiagele, B
    Vespa, PM
    Vinuela, F
    Saver, JL
    [J]. STROKE, 2003, 34 (11) : 2636 - 2640