Optimization of a PV/wind micro-grid for rural housing electrification using a hybrid iterative/genetic algorithm: Case study of Kuala Terengganu, Malaysia

被引:134
作者
Khatib, Tamer [1 ]
Mohamed, Azah [1 ]
Sopian, K. [2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Kebangsaan Malaysia, Solar Energy Res Inst, Bangi 43600, Selangor, Malaysia
关键词
PV/wind systems; Optimization of PV systems; Optimum tilt angle; Inverter size; Micro-grid; WIND; SYSTEMS; METHODOLOGY;
D O I
10.1016/j.enbuild.2011.12.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an optimization for hybrid PV/wind system based on loss of load probability (LLP) and system cost. This paper is divided into three main parts: optimization of PV array, wind turbine and battery, optimum PV array tilt angle and optimization of the inverter size. Firstly, the optimization performed is aimed to select the optimal capacities of the PV array and wind turbine that give minimum system cost. However, the optimization was done using a hybrid iterative/genetic algorithm. The iterative part of the proposed algorithm is applied to generate a set of possible configurations for the proposed system, while the genetic algorithm is applied to find the optimum configuration. Secondly, a model for optimizing the tilt angle of the PV array is presented based on the Liu and Jordan model. Finally, an iterative method for optimizing the inverter size in the proposed system is presented. The results showed that the optimum sizes of the PV array (C-A), wind turbine (C-s) and storage battery (C-B) are 1.1411, 0.7159, and 0.550, respectively, while the optimum inverter's size (Rs) is 1.37. Lastly, by applying the calculated monthly optimum tilt angle, the collected yield of the PV array is increased by 7.96%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:321 / 331
页数:11
相关论文
共 19 条
[1]   Technical and economic assessment of hybrid photovoltaic/wind system with battery storage in Corsica island [J].
Diaf, S. ;
Belhamel, M. ;
Haddadi, M. ;
Louche, A. .
ENERGY POLICY, 2008, 36 (02) :743-754
[2]   A methodology or optimal sizing of autonomous hybrid PV/wind system [J].
Diaf, S. ;
Diaf, D. ;
Belhamel, M. ;
Haddadi, M. ;
Louche, A. .
ENERGY POLICY, 2007, 35 (11) :5708-5718
[3]  
Duffie J.A., 1991, Solar Engineering of Thermal Processes, Vsecond
[4]   Modeling and analysis of solar photovoltaic-electrolyzer-fuel cell hybrid power system integrated with a floriculture greenhouse [J].
Ganguly, A. ;
Misra, D. ;
Ghosh, S. .
ENERGY AND BUILDINGS, 2010, 42 (11) :2036-2043
[5]  
Jordan R., 1962, T ASHRAE, P67
[6]   Generation unit sizing and cost analysis for stand-alone wind, photovoltaic, and hybrid wind/PV systems [J].
Kellogg, WD ;
Nehrir, MH ;
Venkataramanan, G ;
Gerez, V .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1998, 13 (01) :70-75
[7]  
Kenisarin M. M., 1992, Applied Solar Energy, V28, P66
[8]  
Khatib T, 2010, HIGH EFFICIENT STAND
[9]   Methodology for optimal sizing of stand-alone photovoltaic/wind-generator systems using genetic algorithms [J].
Koutroulis, Eftichios ;
Kolokotsa, Dionissia ;
Potirakis, Antonis ;
Kalaitzakis, Kostas .
SOLAR ENERGY, 2006, 80 (09) :1072-1088
[10]   Sizing of hybrid photovoltaic-wind energy systems [J].
Markvart, T .
SOLAR ENERGY, 1996, 57 (04) :277-281