Outlier detection in high-density surface electromyographic signals

被引:57
作者
Marateb, Hamid R. [1 ]
Rojas-Martinez, Monica [2 ]
Mansourian, Marjan [3 ]
Merletti, Roberto [1 ]
Mananas Villanueva, Miguel A. [4 ]
机构
[1] Politecn Torino, Dept Elect, Lab Engn Neuromuscular Syst, Turin, Italy
[2] Tech Univ Catalonia, Biomed Res Networking Ctr Bioengn, Dept ESAII, CIBER BBN,CREB,UPC, Barcelona, Spain
[3] Isfahan Univ Med Sci, Hlth Sch, Dept Biostat & Epidemiol, Esfahan, Iran
[4] Tech Univ Catalonia, Biomed Engn Res Ctr, Dept ESAII, CREB,CIBER BBN,UPC, Barcelona, Spain
关键词
Detection theory; Feature extraction; Logistic regression; Multichannel surface electromyography; Multivariate outlier detection; Robust statistics; INTERFERENCE;
D O I
10.1007/s11517-011-0790-7
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
Recently developed techniques allow the analysis of surface EMG in multiple locations over the skin surface (high-density surface electromyography, HDsEMG). The detected signal includes information from a greater proportion of the muscle of interest than conventional clinical EMG. However, recording with many electrodes simultaneously often implies bad-contacts, which introduce large power-line interference in the corresponding channels, and short-circuits that cause near-zero single differential signals when using gel. Such signals are called 'outliers' in data mining. In this work, outlier detection (focusing on bad contacts) is discussed for monopolar HDsEMG signals and a new method is proposed to identify 'bad' channels. The overall performance of this method was tested using the agreement rate against three experts' opinions. Three other outlier detection methods were used for comparison. The training and test sets for such methods were selected from HDsEMG signals recorded in Triceps and Biceps Brachii in the upper arm and Brachioradialis, Anconeus, and Pronator Teres in the forearm. The sensitivity and specificity of this algorithm were, respectively, 96.9 +/- A 6.2 and 96.4 +/- A 2.5 in percent in the test set (signals registered with twenty 2D electrode arrays corresponding to a total of 2322 channels), showing that this method is promising.
引用
收藏
页码:79 / 89
页数:11
相关论文
共 61 条
[1]
A frequency domain Hampel filter for blind rejection of sinusoidal interference from electromyograms [J].
Allen, David P. .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 177 (02) :303-310
[2]
Angiulli C Pizzuti, 2002, 6 EUR C PRINC PRACT, P15
[3]
[Anonymous], 1936, P NATL I SCI INDIA, DOI DOI 10.1007/S13171-019-00164-5
[4]
[Anonymous], ENCY STAT SCI
[5]
[Anonymous], 1977, Data Analysis and Regression
[6]
[Anonymous], 2006, Digital Image Processing
[7]
[Anonymous], 1973, Pattern Classification and Scene Analysis
[8]
Barnett V., 1994, Outliers in statistical data
[9]
Ben-Gal I, 2005, DATA MINING AND KNOWLEDGE DISCOVERY HANDBOOK, P131, DOI 10.1007/0-387-25465-X_7
[10]
Strong-continuation, contrast-invariant inpainting with a third-order optimal PDE [J].
Bertalmio, Marcelo .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (07) :1934-1938