Tracer kinetic modeling in nuclear cardiology

被引:18
作者
DeGrado, TR
Bergmann, SR
Ng, CK
Raffel, DM
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Columbia Univ, Dept Med, Div Cardiol, New York, NY USA
[3] Yale Univ, Dept Diagnost Radiol, New Haven, CT 06510 USA
[4] Univ Michigan, Dept Radiol, Detroit, MI USA
关键词
D O I
10.1067/mnc.2000.111127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The introduction of tracer kinetic modeling techniques in conjunction with nuclear imaging has allowed the assessment of physiologic processes in the myocardium in a noninvasive and quantitative manner. Alongside the development of novel radiopharmaceuticals for both positron emission tomography and single photon emission computed tomography is the clarification of their pharmacology, pharmacokinetics, and modeling strategies for assessment of physiologic rates from imaging data. Image analysis and tracer kinetic modeling techniques used in nuclear cardiology must address unique considerations related to the heart. The most commonly used tracers and modeling techniques are presently discussed, with particular attention given to methods that allow absolute quantitation of physiologic processes. The applications of these techniques are obvious in research protocols and may find more use in future clinical studies.
引用
收藏
页码:686 / 700
页数:15
相关论文
共 108 条
[1]   Carbon-11 Hydroxyephedrine With Positron Emission Tomography for Serial Assessment of Cardiac Adrenergic Neuronal Function After Acute Myocardial Infarction in Humans [J].
Allman, Kevin C. ;
Wieland, Donald M. ;
Muzik, Otto ;
Degrado, Timothy R. ;
Wolfe, Edwin R., Jr. ;
Schwaiger, Markus .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :368-375
[2]   NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY [J].
ARAUJO, LI ;
LAMMERTSMA, AA ;
RHODES, CG ;
MCFALLS, EO ;
IIDA, H ;
RECHAVIA, E ;
GALASSI, A ;
DESILVA, R ;
JONES, T ;
MASERI, A .
CIRCULATION, 1991, 83 (03) :875-885
[3]   VALIDATION OF [1-C-11]ACETATE AS A TRACER FOR NONINVASIVE ASSESSMENT OF OXIDATIVE-METABOLISM WITH POSITRON EMISSION TOMOGRAPHY IN NORMAL, ISCHEMIC, POSTISCHEMIC, AND HYPEREMIC CANINE MYOCARDIUM [J].
ARMBRECHT, JJ ;
BUXTON, DB ;
SCHELBERT, HR .
CIRCULATION, 1990, 81 (05) :1594-1605
[4]  
BELLINA CR, 1990, J NUCL MED, V31, P1335
[5]   Non-invasive estimation of myocardial efficiency using positron emission tomography and carbon-11 acetate - comparison between the normal and failing human heart [J].
Bengel, FM ;
Permanetter, B ;
Ungerer, M ;
Nekolla, S ;
Schwaiger, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (03) :319-326
[6]   NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY [J].
BERGMANN, SR ;
HERRERO, P ;
MARKHAM, J ;
WEINHEIMER, CJ ;
WALSH, MN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :639-652
[7]   QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15 [J].
BERGMANN, SR ;
FOX, KAA ;
RAND, AL ;
MCELVANY, KD ;
WELCH, MJ ;
MARKHAM, J ;
SOBEL, BE .
CIRCULATION, 1984, 70 (04) :724-733
[8]  
Bergmann SR, 1996, J NUCL MED, V37, P1723
[9]  
BERGMANN SR, 1983, SCIENCE, V220, P1181
[10]  
BERGMANN SR, 1992, POSITRON EMISSION TO, P97