Solid-phase microextraction fibre-water distribution constants of more hydrophobic organic compounds and their correlations with octanol-water partition coefficients

被引:75
作者
Paschke, A
Popp, R
机构
[1] UFZ Helmholtz Ctr Environm Res, Environm Res Ctr, Dept Chem Ecotoxicol, D-04318 Leipzig, Germany
[2] UFZ Helmholtz Ctr Environm Res, Environm Res Ctr, Dept Analyt Chem, D-04318 Leipzig, Germany
关键词
fibre-water distribution constants; octanol-water partition coefficients; solid-phase microextraction; polynuclear aromatic hydrocarbons; chlorobenzenes; polychlorinated biphenyls; pesticides; organochlorine compounds;
D O I
10.1016/S0021-9673(03)00538-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fibre coating-water distribution constants (K,,) of more hydrophobic chemicals were determined with six different solid-phase microextraction fibre types (including a polyoctylmethylsiloxane (C,) prototype) by fibre exposure to agitated large-volume water samples lasting several days. The results obtained are comparable with K-fw values obtained under dynamic conditions. Octanol-water partition coefficients (K-OW) were measured with the mixture of distributing substances to examine log K-fw-log K-OW relationships based on a consistent dataset. K-fw values obtained with liquid polymer fibre coatings correlate reasonably well with the hydrophobicity of the test compounds (with decreasing sensitivity in the following order: 7 mum polydimethylsiloxane (PDMS)>100 mum PDMS>C8>polyacrylate) whereas this is not the case with the PDMS-divinylbenzene (DVB) and Carbowax-DVB fibres, partially porous coatings which provide the highest Kfw values for all substances tested. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 41 条
[1]  
[Anonymous], 014201 US GEOL SURV
[2]   OCTANOL - WATER PARTITION COEFFICIENTS(P) - MEASUREMENT, ESTIMATION, AND INTERPRETATION, PARTICULARLY FOR CHEMICALS WITH P-GREATER THAN-10(5) [J].
BROOKE, DN ;
DOBBS, AJ ;
WILLIAMS, N .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1986, 11 (03) :251-260
[3]   Solid-phase microextraction as a method for estimating the octanol-water partition coefficient [J].
Dean, JR ;
Tomlinson, WR ;
Makovskaya, V ;
Cumming, R ;
Hetheridge, M ;
Comber, M .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :130-133
[4]   DETERMINATION OF OCTANOL WATER PARTITION-COEFFICIENTS FOR HYDROPHOBIC ORGANIC-CHEMICALS WITH THE SLOW-STIRRING METHOD [J].
DEBRUIJN, J ;
BUSSER, F ;
SEINEN, W ;
HERMENS, J .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1989, 8 (06) :499-512
[5]   Determination of distribution coefficients of priority polycyclic aromatic hydrocarbons using solid-phase microextraction [J].
Doong, RA ;
Chang, SM .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3647-3652
[6]   Effect of the various parameters governing solid-phase microextraction for the trace-determination of pesticides in water [J].
Dugay, J ;
Miège, C ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (01) :27-42
[7]   Effect of sample volume on quantitative analysis by solid-phase microextraction .1. Theoretical considerations [J].
Gorecki, T ;
Pawliszyn, J .
ANALYST, 1997, 122 (10) :1079-1086
[8]   The effect of sample volume on quantitative analysis by solid phase microextraction -: Part 2.: Experimental verification [J].
Górecki, T ;
Khaled, A ;
Pawliszyn, J .
ANALYST, 1998, 123 (12) :2819-2824
[9]  
LEO A, 2001, MEDCHEM 01
[10]  
Leslie HA, 2002, ENVIRON TOXICOL CHEM, V21, P229, DOI [10.1897/1551-5028(2002)021<0229:BSPMTP>2.0.CO