Tantalum as a buffer layer in diamond-like carbon coated artificial hip joints

被引:22
作者
Kiuru, M
Alakoski, E
Tiainen, VM
Lappalainen, R
Anttila, A
机构
[1] Univ Helsinki, Dept Phys Sci, FIN-00014 Helsinki, Finland
[2] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS | 2003年 / 66B卷 / 01期
关键词
tantalum coating; acid resistance; artificial hip joint; total hip replacement;
D O I
10.1002/jbm.b.10029
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The acid resistance of tantalum coated and uncoated human hip joint prostheses was studied with commercial CrCoMo acetabullar cups. The samples were exposed to 10% HCl solution and the quantities of dissolved Cr, Co, and Mo were measured with proton-induced X-ray emission (PIXE). The absolute quantities were obtained with the use of Cr and Se solution standards. Tantalum coatings (thicknesses 4-6 mum) were prepared in vacuum with magnetron sputtering. Tantalum coating decreased the corrosion rate by a factor of 10(6). As a spinoff from recent wear tests on artificial hip joints it was shown that tantalum has excellent mechanical properties as an intermediate layer of diamond-like carbon (DLC) coatings. When tantalum was tested together with DLC on three metal-on-metal hip joint pairs in a hip simulator, no observable defects occurred during 15 million walking cycles with a periodic 50-300-kg load (Paul curve). (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 21 条
[1]   ON THE OPTIMIZATION OF AN EXTERNAL PIXE ARRANGEMENT [J].
ANTTILA, A ;
RAISANEN, J ;
LAPPALAINEN, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 12 (02) :245-247
[2]  
Anttila A, 1999, NEW DIAM FRONT C TEC, V9, P283
[3]   Superior attachment of high-quality hydrogen-free amorphous diamond films to solid materials [J].
Anttila, A ;
Lappalainen, R ;
Tiainen, VM ;
Hakovirta, M .
ADVANCED MATERIALS, 1997, 9 (15) :1161-&
[4]  
Anttila A, 1992, US Patent, Patent No. 5078848
[5]  
Black Jonathan, 1994, Clinical Materials, V16, P167, DOI 10.1016/0267-6605(94)90113-9
[6]   Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[7]  
Greenwood N.N., 2012, Chemistry of the elements
[8]  
Hacking SA, 2000, J BIOMED MATER RES, V52, P631
[9]  
JOHANSSON SAE, 1988, NOVEL TECNIQUE ELEME
[10]   SEQUENTIAL-CHANGES OF MINERAL AND TRACE-ELEMENTS IN MILK DURING THE COURSE OF ENDOTOXIN-INDUCED MASTITIS AS ANALYZED BY PARTICLE INDUCED X-RAY (PIXE), INDUCED GAMMA-RAY EMISSION (PIGE) AND ION-SELECTIVE ELECTRODES [J].
LAPPALAINEN, R ;
KAARTINEN, L ;
VEIJALAINEN, K ;
KUOSA, PL ;
SANKARI, S ;
PYORALA, S ;
SANDHOLM, M .
JOURNAL OF VETERINARY MEDICINE SERIES B-ZENTRALBLATT FUR VETERINARMEDIZIN REIHE B-INFECTIOUS DISEASES AND VETERINARY PUBLIC HEALTH, 1988, 35 (09) :664-676