Confocal fluorescence coincidence analysis: An approach to ultra high-throughput screening

被引:109
作者
Winkler, T [1 ]
Kettling, U [1 ]
Koltermann, A [1 ]
Eigen, M [1 ]
机构
[1] Max Planck Inst Biophys Chem, Dept Biochem Kinet, D-37077 Gottingen, Germany
关键词
D O I
10.1073/pnas.96.4.1375
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fluorescence-based assay technologies play an increasing role in high-throughput screening. They can be classified into different categories: fluorescence polarization, time-resolved fluorescence, fluorescence resonance energy transfer, and fluorescence correlation spectroscopy. In this work we present an alternative analytical technique for high-throughput screening, which we call confocal fluorescence coincidence analysis. Confocal fluorescence coincidence analysis extracts fluorescence fluctuations that occur coincidently in two different spectral ranges from a tiny observation volume of below 1 fl, This procedure makes it possible to monitor whether an association between molecular fragments that are labeled with different fluorophores is established or broken. Therefore, it provides access to the characterization of a variety of cleavage and ligation reactions in biochemistry, Confocal fluorescence coincidence analysis is a very sensitive and ultrafast technique with readout times of 100 ms and below. This feature is demonstrated by means of a homogeneous assay for restriction endonuclease EcoRI. The presented achievements break ground for throughput rates as high as 10(6) samples per day with using only small amounts of sample substance and therefore constitute a solid base for screening applications in drug discovery and evolutionary biotechnology.
引用
收藏
页码:1375 / 1378
页数:4
相关论文
共 10 条
[1]   Fluorescence correlation spectroscopy: lead discovery by miniaturized HTS [J].
Auer, M ;
Moore, KJ ;
Meyer-Almes, FJ ;
Guenther, R ;
Pope, AJ ;
Stoeckli, KA .
DRUG DISCOVERY TODAY, 1998, 3 (10) :457-465
[2]   SORTING SINGLE MOLECULES - APPLICATION TO DIAGNOSTICS AND EVOLUTIONARY BIOTECHNOLOGY [J].
EIGEN, M ;
RIGLER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (13) :5740-5747
[3]   Real-time enzyme kinetics monitored by dual-color fluorescence cross-correlation spectroscopy [J].
Kettling, U ;
Koltermann, A ;
Schwille, P ;
Eigen, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (04) :1416-1420
[4]   Rapid assay processing by integration of dual-color fluorescence cross-correlation spectroscopy: High throughput screening for enzyme activity [J].
Koltermann, A ;
Kettling, U ;
Bieschke, J ;
Winkler, T ;
Eigen, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (04) :1421-1426
[5]   FLUORESCENCE CORRELATION SPECTROSCOPY .2. EXPERIMENTAL REALIZATION [J].
MAGDE, D ;
ELSON, EL ;
WEBB, WW .
BIOPOLYMERS, 1974, 13 (01) :29-61
[6]   Fluorescence correlation spectroscopy: Diagnostics for sparse molecules [J].
Maiti, S ;
Haupts, U ;
Webb, WW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (22) :11753-11757
[7]  
RIGLER R, 1993, EUR BIOPHYS J BIOPHY, V22, P169, DOI 10.1007/BF00185777
[8]  
Rigler R., 1990, BIOSCIENCE, V3, P180
[9]   Light on high-throughput screening: Fluorescence-based assay technologies [J].
Rogers, MV .
DRUG DISCOVERY TODAY, 1997, 2 (04) :156-160
[10]   Dual-color fluorescence cross-correlation spectroscopy for multicomponent diffusional analysis in solution [J].
Schwille, P ;
MeyerAlmes, FJ ;
Rigler, R .
BIOPHYSICAL JOURNAL, 1997, 72 (04) :1878-1886