Determination of (ultra)trace amounts of antimony(III) in water by flow injection on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry

被引:69
作者
Yan, XP [1 ]
VanMol, W [1 ]
Adams, F [1 ]
机构
[1] UNIV ANTWERP,DEPT CHEM,B-2610 ANTWERP,BELGIUM
关键词
flow injection; on-line preconcentration; knotted reactor; antimony(III); water; electrothermal atomic absorption spectrometry;
D O I
10.1039/an9962101061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection on-line sorption preconcentration system has been synchronously coupled to an ETAAS system for the selective determination of (ultra)trace amounts of Sb-III in water, The determination was achieved by selective complexation of Sb-III with ammonium pyrrolidine dithiocarbamate (APDC) at a wide range of sample acidity (0-1 mol l(-1) HCl), sorption of the complex onto the inner walls of a knotted reactor made from (100 cm long x 0.5 mm id) PTFE tubing, quantitative elution with 35 mu l of ethanol and subsequent ETAAS detection. In order to minimize dispersion and to reduce the eluent volume required for the quantitative elution, an air flow was used to drive the eluent elution and to deliver all the eluate into an unpreheated polycrystalline graphite tube without a platform, Precise timing was not needed for analyte elution and eluate introduction, ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample, Using a preconcentration time of 30 s and a sample loading flow rate of 5.4 ml min(-1), an enhancement factor of 30 was obtained in comparison with direct injection of 35 mu l aqueous solution, resulting in a sampling frequency of 42 samples h(-1). The detection limit (3s) was 0.021 mu g l(-1) and the precision was 2.9% (RSD) for eleven replicate determinations at 1 mu g l(-1). The introduction of an efficient wash step before elution with the addition of APDC to the wash medium permitted the use of simple aqueous standards for direct calibration in the analysis of sea-water. The accuracy of the proposed method was demonstrated by analysing synthetic mixtures and spiked sea-water.
引用
收藏
页码:1061 / 1067
页数:7
相关论文
共 26 条
[1]   DETERMINATION OF ANTIMONY(III), ANTIMONY(V), AND METHYLANTIMONY SPECIES IN NATURAL-WATERS BY ATOMIC-ABSORPTION SPECTROMETRY WITH HYDRIDE GENERATION [J].
ANDREAE, MO ;
ASMODE, JF ;
FOSTER, P ;
VANTDACK, L .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1766-1771
[2]  
BODE H, 1957, Z ANAL CHEM, V157, P414
[3]   DETERMINATION OF COPPER IN WATER AND RICE SAMPLES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE ADSORPTION PRECONCENTRATION USING A KNOTTED REACTOR [J].
CHEN, HW ;
XU, SK ;
FANG, ZL .
ANALYTICA CHIMICA ACTA, 1994, 298 (02) :167-173
[4]   SELECTIVE DETERMINATION OF ARSENIC (III, V), ANTIMONY (III, V), SELENIUM (IV, VI) AND TELLURIUM (IV, VI) BY EXTRACTION AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
CHUNG, CH ;
IWAMOTO, E ;
YAMAMOTO, M ;
YAMAMOTO, Y .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (2-3) :459-466
[5]  
Craig, 1986, ORGANOMETALLIC COMPO
[6]   SIMULTANEOUS DETERMINATION OF INORGANIC ARSENIC AND ANTIMONY SPECIES IN NATURAL-WATERS USING SELECTIVE HYDRIDE GENERATION WITH GAS-CHROMATOGRAPHY PHOTOIONIZATION DETECTION [J].
CUTTER, LS ;
CUTTER, GA ;
SANDIEGOMCGLONE, MLC .
ANALYTICAL CHEMISTRY, 1991, 63 (11) :1138-1142
[7]  
DELACALLEGUNTIN.MB, 1991, ANAL CHIM ACTA, V252, P161
[8]   FRUCTOSE-6-PHOSPHATE KINASE IMMOBILIZED ON CONTROLLED-PORE GLASS AS A SUBSTRATE FOR SELECTIVE SEPARATION OF ANTIMONY(III) [J].
DELACALLEGUNTINAS, MB ;
MADRID, Y ;
CAMARA, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (05) :745-748
[9]  
Fang Z., 1995, FLOW INJECTION ATOMI
[10]  
Fang Z., 1993, FLOW INJECTION SEPAR