Hepatitis C virus RNA assays - A comparison of SuperQuant and Monitor

被引:3
作者
Hadziyannis, E
Hadziyannis, A
Yen-Lieberman, B
Kiwi, ML
Hodnick, S
Spanou, F
Starkey, C
Younossi, ZM
机构
[1] INOVA Fairfax Hosp, Ctr Liver Dis, Dept Med, Falls Church, VA 22042 USA
[2] Hippokratio Gen Hosp, Acad Dept Med, Athens, Greece
[3] Hippokratio Gen Hosp, Natl Ctr Communicable Dis Liver, Athens, Greece
[4] Cleveland Clin Fdn, Dept Gastroenterol, Cleveland, OH 44195 USA
[5] Cleveland Clin Fdn, Dept Clin Pathol, Cleveland, OH 44195 USA
关键词
HCV RNA; viral load; polymerase chain reaction quantification;
D O I
10.1097/00004836-200107000-00011
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Hepatitis C RNA testing has been used extensively to assess the efficacy of antiviral therapy and has increasingly become an integral part of clinical management of patients with chronic hepatitis C. A variety of commercially available hepatitis C virus (HCV) RNA tests are used to detect HCV RNA qualitatively or quantitatively. These commercial tests have fundamental differences that are reflected on the values they generate. We compared two widely used assays, HCV SuperQuant (SQ) and Amplicor HCV Monitor (M1 and M2), in sera of patients with chronic hepatitis C. A total of 506 sera from 79 patients were tested with both assays. The data were logarithmically transformed and analyzed by linear regression and measurement of agreement. Two hundred thirty-eight sera had HCV RNA values within the dynamic range of both assays. The correlation between the assays was fair, with a correlation coefficient (r) of 0.699. Overall, SQ generated higher values than M1 with a mean difference of 0.558 log (SD = 0.624). One hundred ninety-four (38%) and 121 (24%) of the sera were below the dynamic range of M1 and SQ, respectively. Seventy-three sera, undetectable by M1, were positive by SQ. The Amplicor HCV Monitor 2.0 (M2) was performed in 66 sera. All were positive by SQ and M2, but only 38 were within the dynamic range of M1. The correlations between these tests were good (r = 0.68-0.78), but the agreement was rather poor. In conclusion, this study confirms that both SQ and M2 are more sensitive than M1. Additionally, our results show rather poor agreements between these assays. The recent attempts in standardizing the reporting of these assays should make their results more easily interchangeable.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 16 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   SERIAL QUANTITATIVE-DETERMINATION OF HEPATITIS-C VIRUS-RNA LEVELS AFTER LIVER-TRANSPLANTATION - A USEFUL TEST FOR DIAGNOSIS OF HEPATITIS-C VIRUS REINFECTION [J].
DUVOUX, C ;
PAWLOTSKY, JM ;
CHERQUI, D ;
VANNHIEU, JT ;
METREAU, JM ;
FAGNIEZ, PL ;
DUVAL, J ;
ZAFRANI, ES ;
DHUMEAUX, D .
TRANSPLANTATION, 1995, 60 (05) :457-461
[3]   ASSESSMENT OF HEPATITIS-C VIREMIA USING MOLECULAR AMPLIFICATION TECHNOLOGIES - CORRELATIONS AND CLINICAL IMPLICATIONS [J].
GRETCH, DR ;
DELAROSA, C ;
CARITHERS, RL ;
WILLSON, RA ;
WILLIAMS, B ;
COREY, L .
ANNALS OF INTERNAL MEDICINE, 1995, 123 (05) :321-329
[4]   Evaluation of two methods for quantitation of hepatitis C virus RNA [J].
Hadziyannis, E ;
Fried, MW ;
Nolte, FS .
MOLECULAR DIAGNOSIS, 1997, 2 (01) :39-46
[5]   Comparison of plasma virus loads among individuals infected with hepatitis C virus (HCV) genotypes 1, 2, and 3 by Quantiplex HCV RNA assay versions 1 and 2, Roche monitor assay, and an in-house limiting dilution method [J].
Hawkins, A ;
Davidson, F ;
Simmonds, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) :187-192
[6]   Quantitation of HCV viraemia by branched DNA signal amplification in patients treated with alpha-interferon - A longitudinal study [J].
Iuliano, R ;
Pizzigallo, AM ;
Alecci, A ;
Barsanti, L ;
Trovato, R ;
Forastieri, G ;
Lico, S ;
Palmieri, C ;
Brizzi, M ;
Marino, N ;
Mecocci, L ;
CeccheriniNelli, L .
INFECTION, 1996, 24 (04) :292-296
[7]   Comparative evaluation of hepatitis C virus RNA quantitation by branched DNA, NASBA, and monitor assays [J].
Lunel, F ;
Cresta, P ;
Vitour, D ;
Payan, C ;
Dumont, B ;
Frangeul, L ;
Reboul, D ;
Brault, C ;
Piette, JC ;
Huraux, JM .
HEPATOLOGY, 1999, 29 (02) :528-535
[8]  
MARTINOTPEIGNOUX M, 1995, HEPATOLOGY, V22, P1050, DOI 10.1002/hep.1840220406
[9]  
Niesters HGM, 1998, HEPATOLOGY, V28, p566A
[10]  
Pageaux G P, 1997, Liver Transpl Surg, V3, P501