New approach to oxygen requirement for low-load activated sludge

被引:9
作者
Charpentier, J [1 ]
Martin, G [1 ]
机构
[1] INST TECH GAZ & AIR,F-35000 RENNES,FRANCE
关键词
activated sludge; wastewater treatment; oxygen requirement; modelling; energy savings; nutrient removal; ORP regulation;
D O I
10.1016/0043-1354(96)00129-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-load activated sludge treatment plants are by far the most numerous and are continuing to develop given their enhanced capacity for nitrogen removal. In general, the electrical consumption of aerators accounts for around 80% of total electrical consumption. It can therefore easily be understood that it is important to be able to evaluate the oxygen requirement for biological treatment as accurately as possible. This evaluation of oxygen requirement is made by the designer during the project phase, using the conventional formula [O-2 = 1/alpha(a'Le+b'Xv+c'N)]. While this approach is entirely satisfactory for the designer (who essentially needs to know the adequate oxygenation capacity), it meets the needs of the operator only imperfectly; the latter needs to know the specific electrical consumption of the aerators as accurately as possible (SEC-kWh.kgBOD(5)(-1)). It is for this reason that an alternative method has been developed allowing calculation of the oxygen requirement for biological treatment (ODCW- kgO(2).kgBOD(5)(-1)) and specific aerator consumption (SEC-kWh.kgBOD(5)(-1)) for low-load activated sludge type plants (Charpentier, 1988). Initially, an ODCW-standard value is obtained, by calculation or from a graph, from the desired concentration in TKN or NH4+. N for the effluent. ODCWstandard=mass of Oxygen which the aerators must be able to dissolve in clean water for 1 kg of BOD5 to be eliminated in ''standard'' operating conditions. For ''non-standard'' operating conditions (volumetric load <0.18 kg BOD5.m(-1).d(-1); [VSS](aeration)not equal 3 g.l(-1); [TKN/BOD5](influent)not equal 0.25; [BOD5](influent) > 1000 mg O-2.1(-1)), the ODCWstandard value must be combined with correction factors k(1), k(2), k(3), and k(4) of which the values and conditions of application have been defined: ODCWplant=ODCW(standard)xk(1)k(2)k(3)k(4) SED=ODCWplant/SOTR Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:2347 / 2356
页数:10
相关论文
共 13 条
[1]   OXIDATION-REDUCTION POTENTIAL (ORP) REGULATION - A WAY TO OPTIMIZE POLLUTION REMOVAL AND ENERGY SAVINGS IN THE LOW LOAD ACTIVATED-SLUDGE PROCESS [J].
CHARPENTIER, J ;
FLORENTZ, M ;
DAVID, G .
WATER SCIENCE AND TECHNOLOGY, 1987, 19 (3-4) :645-655
[2]  
CHARPENTIER J, 1988, THESIS U RENNES 1
[3]  
*CTGREF, 1980, PERF SYST AER STAT E
[4]  
DAVID G, 1984, UN GRAPHIQUE UTILISA
[5]   TESTS ON AERATORS - CONCLUSIONS DRAWN FROM 500 CLEAN WATER TESTS CONDUCTED IN 200 DIFFERENT SEWAGE-TREATMENT PLANTS .1. TEST PROCEDURE [J].
HEDUIT, A ;
RACAULT, Y .
WATER RESEARCH, 1983, 17 (01) :97-103
[6]   TESTS ON AERATORS - CONCLUSIONS DRAWN FROM 500 CLEAN WATER TESTS CONDUCTED IN 200 DIFFERENT SEWAGE-TREATMENT PLANTS .2. DATA INTERPRETATION [J].
HEDUIT, A ;
RACAULT, Y .
WATER RESEARCH, 1983, 17 (03) :289-297
[7]  
KAYSER R, 1979, PROG WATER TECHNOL, V11, P23
[8]  
Martin G., 1979, PROBLEME AZOTE EAUX
[9]   EFFECTS OF ALPHA-FACTOR, BETA-FACTOR AND THETA-FACTOR UPON THE DESIGN, SPECIFICATION AND OPERATION OF AERATION SYSTEMS [J].
STENSTROM, MK ;
GILBERT, RG .
WATER RESEARCH, 1981, 15 (06) :643-654
[10]  
TARDIEU B, 1972, ETUDE MESURE CAPA IT