Arthroplasty options for the young patient

被引:46
作者
Bourne, RB [1 ]
Barrack, R [1 ]
Rorabeck, CH [1 ]
Salehi, A [1 ]
Good, V [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
D O I
10.1097/01.blo.0000193813.08458.e2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our purpose was to determine whether metal femoral heads scratch with in vivo use, to characterize the scratching that occurs, and to determine whether this scratching affected polyethylene wear. Assessment of 133 consecutive retrieved femoral heads showed that metal femoral heads do scratch with in vivo use, that cobalt-chromium femoral heads are more scratch resistant than titanium alloy heads, and that scratching seems to be time dependent. Profilmetry studies showed that all roughness parameters (average roughness, maximum peak to lowest valley distance, mean peak height above the mean surface line, estimate of small peaks above the main plateau of the surface, and estimate of the depth of the valleys below the mean plateau of the surface with the exception of the symmetry of the profile about its mean line) showed increased roughness with time of use. Cobalt-chromium and Oxinium femoral heads were damaged in a dislocation model. Assessment of these femoral heads in a wear simulator revealed that against conventional polyethylene, a damaged Oxinium femoral head had no more wear than a new cobalt-chromium articulation on the same polyethylene (36.5(3)/million cycles versus 38.4 mm(3)/million). Against cross-linked polyethylene, a damaged Oxinium femoral head had minimal wear (1.5 nun cubed per Mc).
引用
收藏
页码:159 / 167
页数:9
相关论文
共 47 条
[1]
Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]
[Anonymous], BONE IMPLANT INTERFA
[3]
Microstructural investigation of the oxide scale on Zr-2.5Nb and its interface with the alloy substrate [J].
Benezra, V ;
Mangin, S ;
Treska, M ;
Spector, M ;
Hunter, G ;
Hobbs, LW .
BIOMEDICAL MATERIALS-DRUG DELIVERY, IMPLANTS AND TISSUE ENGINEERING, 1999, 550 :337-342
[4]
Third-body wear of highly cross-linked polyethylene in a hip simulator [J].
Bragdon, CR ;
Jasty, M ;
Muratoglu, OK ;
O'Connor, DO ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :553-561
[5]
Local head roughening as a factor contributing to variability of total hip wear: A finite element analysis [J].
Brown, TD ;
Stewart, KJ ;
Nieman, JC ;
Pedersen, DR ;
Callaghan, JJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (06) :691-698
[6]
Soft-tissue balancing of the hip - The role of femoral offset restoration [J].
Charles, MN ;
Bourne, RB ;
Davey, JR ;
Greenwald, AS ;
Morrey, BF ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :1078-1088
[7]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P317
[8]
The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :6-16
[9]
DOWSON D, 1987, WEAR, V119, P227
[10]
Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses [J].
Endo, M ;
Tipper, JL ;
Barton, DC ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H2) :111-122