Specific and sensitive detection of Neisseria gonorrhoeae in clinical specimens by real-time PCR

被引:49
作者
Geraats-Peters, CWM
Brouwers, M
Schneeberger, PM
van der Zanden, AGM
Bruisten, SM
Weers-Pothoff, G
Boel, CHE
van den Brule, AJC
Harmsen, HG
Hermans, MHA
机构
[1] Jeroen Bosch Hosp, Multidisciplinary Lab Mol Diagnost, NL-5200 ME sHertogenbosch, Netherlands
[2] Jeroen Bosch Hosp, Reg Lab Med Microbiol, NL-5200 ME sHertogenbosch, Netherlands
[3] Gelre Hosp, Apeldoorn, Netherlands
[4] Municipal Hlth Serv, GG&GD, Apeldoorn, Netherlands
[5] PAMM, Lab Pathol & Microbiol, Velhoven, Netherlands
关键词
D O I
10.1128/JCM.43.11.5653-5659.2005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Early diagnosis of Neisseria gonorrhoeae infections is important with regard to patients' health and infectivity. We report the development of a specific and sensitive TaqMan assay for the detection of N. gonorrhoeae in clinical samples. The target sequence is a 76-bp fragment of the 5' untranslated region of the opa genes that encode opacity proteins. A panel of 448 well-defined N. gonorrhoeae isolates was used to evaluate and optimize the assay. The method employs two minor-groove binding probes, one of them recognizing a newly identified sequence in the opa genes. Testing a large panel of related and unrelated microorganisms revealed that other Neisseria strains and other microorganisms tested negative in the opa test. With a lower detection limit of one genome per reaction, the opa test appeared more sensitive than both the COBAS AMPLICOR (Roche Diagnostics Nederland BV, Almere, The Netherlands) and a LightCycler 16S rRNA test. Analysis of a panel of 122 COBAS AMPLICOR-positive samples revealed that 68% were negative in both the 16S rRNA test and the opa assay (confirming that the COBAS AMPLICOR test produces false positives), while 30% were positive in both assays. Three samples were opa positive and 16S rRNA negative, which may be due to the higher sensitivity of the opa assay. We conclude that the opa gene-based real-time amplification assay offers a sensitive, specific, semiquantitative, and reliable assay suitable for the detection of N. gonorrhoeae in clinical specimens and/or for confirmation of less specific tests.
引用
收藏
页码:5653 / 5659
页数:7
相关论文
共 42 条
[1]   Evaluation of a strand displacement amplification assay (BD ProbeTec-SDA) for detection of Neisseria gonorrhoeae in urine specimens [J].
Akduman, D ;
Ehret, JM ;
Messina, K ;
Ragsdale, S ;
Judson, FN .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (01) :281-283
[2]   Multiplex AMPLICOR PCR screening for Chlamydia trachomatis and Neisseria gonorrhoeae in women attending non-sexually transmitted disease clinics [J].
Bassiri, M ;
Mardh, PA ;
Domeika, M ;
Borendal, N ;
Capdevila, CC ;
Creatsas, G ;
Douvier, S ;
Guashino, S ;
HenrySuchet, J ;
Hopwood, J ;
Kliment, M ;
Lazdane, G ;
Mallinson, H ;
Nagy, E ;
Neuer, A ;
Nottin, P ;
Palacios, S ;
Penngy, G ;
Peterek, J ;
Rebelo, D ;
vanSanten, M ;
Tchoudomirova, K ;
Templeton, A ;
Unzeitig, V .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (10) :2556-2560
[3]   INTERACTIONS OF GONOCOCCI WITH HELA-CELLS - ATTACHMENT, DETACHMENT, REPLICATIONS, PENETRATION, AND THE ROLE OF PROTEIN-II [J].
BESSEN, D ;
GOTSCHLICH, EC .
INFECTION AND IMMUNITY, 1986, 54 (01) :154-160
[4]   THE OPACITY PROTEINS OF NEISSERIA-GONORRHOEAE STRAIN MS11 ARE ENCODED BY A FAMILY OF 11 COMPLETE GENES [J].
BHAT, KS ;
GIBBS, CP ;
BARRERA, O ;
MORRISON, SG ;
JAHNIG, F ;
STERN, A ;
KUPSCH, EM ;
MEYER, TF ;
SWANSON, J .
MOLECULAR MICROBIOLOGY, 1991, 5 (08) :1889-1901
[5]   Evaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples [J].
Boel, CHE ;
van Herk, CMC ;
Berretty, PJM ;
Onland, GHW ;
van den Brule, AJC .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (05) :2231-2235
[6]   Selection of Opa(+) Neisseria gonorrhoeae by limited availability of normal human serum [J].
Bos, MP ;
Hogan, D ;
Belland, RJ .
INFECTION AND IMMUNITY, 1997, 65 (02) :645-650
[7]   Multicenter validation of the cppB gene as a PCR target for detection of Neisseria gonorrhoeae [J].
Bruisten, SM ;
Noordhoek, GT ;
van den Brule, AJC ;
Duim, B ;
Boel, CHE ;
El-Faouzi, K ;
du Maine, R ;
Mulder, S ;
Luijt, D ;
Schirm, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (09) :4332-4334
[8]   Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by ligase chain reaction-based assays with clinical specimens from various sites: Implications for diagnostic testing and screening [J].
Buimer, M ;
VanDoornum, GJJ ;
Ching, S ;
Peerbooms, PGH ;
Plier, PK ;
Ram, D ;
Lee, HH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (10) :2395-2400
[9]  
Centers for Disease Control and Prevention (CDC), 2002, MMWR Morb Mortal Wkly Rep, V51, P709
[10]   ADHERENCE OF PILUS(-) OPA(+) GONOCOCCI TO EPITHELIAL-CELLS IN-VITRO INVOLVES HEPARAN-SULFATE [J].
CHEN, T ;
BELLAND, RJ ;
WILSON, J ;
SWANSON, J .
JOURNAL OF EXPERIMENTAL MEDICINE, 1995, 182 (02) :511-517