Safety of a new transpulmonary echocontrast agent (Albunex(R)) in repeated echocardiographic studies in patients

被引:16
作者
Geny, B
Bischoff, P
Muan, B
Piquard, F
Thiranos, JC
Epailly, E
Lambrechs, M
JuelsrudVebner, A
Eisenmann, B
Haberey, P
机构
[1] UNIV STRASBOURG 1,SERV IMMUNOL,FAC MED STRASBOURG,F-67085 STRASBOURG,FRANCE
[2] UNIV STRASBOURG 1,SERV CHIRURG CARDIOVASC,FAC MED STRASBOURG,F-67085 STRASBOURG,FRANCE
[3] NYCOMED IMAGING SA,OSLO,NORWAY
关键词
Albunex(R); contrast echocardiography; immune system; safety microspheres;
D O I
10.1002/clc.4960200206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and hypothesis: Multiple contrast-enhanced echocardiographic studies are to be expected in patients with cardiac ischemic disease, but the sonication process used to produce the echocontrast agent Albunex(R) may result in new epitopes that could cause an immunogenic response. Methods: Repeated exposures to intravenous Albunex over a period of time long enough to allow development of an eventual immune reaction were performed in 12 patients while monitoring for lymphocyte transformation, microsphere specific IgE and IgG antibodies, and systemic, pulmonary artery, capillary wedge, and right atrial pressures, as well as cardiac output, left ventricular fractional shortening, and blood gases. Results: No significant H-3-thymidine incorporation and thus no specific blastic transformation of the patients' lymphocytes were observed either for high or low Albunex concentrations, corresponding to the expected hepatic and plasma concentrations of microspheres. No formation of microsphere-specific IgE and IgG antibodies was observed after the first or second Albunex exposure. Furthermore, no clinically significant hemodynamic or respiratory adverse reactions were observed in any patient. Conclusion: These results suggest that repeated exposures to intravenous Albunex induce no adverse effect on the cellular and humoral immune systems and on left and right heart hemodynamics in patients.
引用
收藏
页码:111 / 115
页数:5
相关论文
共 31 条
[1]   IMMUNOLOGICAL REACTIONS OF HUMAN RECIPIENTS TO REPEATED EXPOSURES TO ALBUNEX MICROSPHERES [J].
BARNHART, JL ;
HARADA, M ;
LYLE, LR ;
SARAVIS, CA .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S192-S193
[2]   LACK OF AN IMMUNE-RESPONSE TO ALBUNEX(R), A NEW ULTRASOUND CONTRAST AGENT BASED ON AIR-FILLED ALBUMIN MICROSPHERES [J].
CHRISTIANSEN, C ;
VEBNER, AJ ;
MUAN, B ;
VIK, H ;
HAIDER, T ;
NICOLAYSEN, H ;
SKOTLAND, T .
INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY, 1994, 104 (04) :372-378
[3]  
CROUSE LJ, 1992, AM J CARDIOL, V69, pA42
[4]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[5]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ECHO CONTRAST AGENT IN ECHOCARDIOGRAPHIC STUDIES IN PATIENTS [J].
GENY, B ;
METTAUER, B ;
MUAN, B ;
BISCHOFF, P ;
EPAILLY, E ;
PIQUARD, F ;
EISENMANN, B ;
HABEREY, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1193-1198
[6]  
GENY BP, 1990, CIRCULATION, V82, P95
[7]  
GREENBERGER PA, 1984, J ALLERGY CLIN IMMUN, V4, P600
[8]   AIR-FILLED PROTEINACEOUS MICROBUBBLES - SYNTHESIS OF AN ECHO-CONTRAST AGENT [J].
GRINSTAFF, MW ;
SUSLICK, KS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (17) :7708-7710
[9]  
HELLEBUST H, 1993, BIOTECHNOL APPL BIOC, V18, P227
[10]   CLINICAL-APPLICATIONS OF MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY [J].
KAUL, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (20) :H46-H55