Design of a new type of coating for the controlled release of heparin

被引:41
作者
Hinrichs, WLJ
tenHoopen, HWM
Wissink, MJB
Engbers, GHM
Feijen, J
机构
[1] UNIV TWENTE, FAC CHEM TECHNOL, NL-7500 AE ENSCHEDE, NETHERLANDS
[2] UNIV TWENTE, INST BIOMED TECHNOL, NL-7500 AE ENSCHEDE, NETHERLANDS
关键词
antithrombogenicity; controlled release; heparin; hydrolysis of covalent bonds; porous structures;
D O I
10.1016/S0168-3659(96)01571-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Thrombus formation at the surface of blood contacting devices can be prevented by local release of heparin. Preferably, the release rate should be constant for prolonged periods of time. The minimum heparin release rate to achieve thromboresistance will be different for various applications and should therefore be adjustable, In this study a new type of heparin release system is presented which may be applied as a coating for blood contacting devices. The system is based on the covalent immobilization of heparin onto porous structures via hydrolysable bonds. This approach was evaluated by the immobilization of heparin onto a porous cellulosic substrate via ester bonds. Cuprophan was used as a model substrate and N,N'-carbonyldiimidazole as a coupling agent. Heparinized Cuprophan incubated in phosphate buffered saline showed a release of heparin due to the hydrolysis of the ester bonds between heparin and Cuprophan. The release rate could be easily adjusted by varying the amount of coupling agent used during immobilization. Cuprophan with a rather stable heparin coating (release rate: 6.1 mU/cm(2) . h) and Cuprophan which shows a substantial release of heparin (release rate up to 23.0 mU/cm(2) . h) could be prepared. Except when the release was relatively high, release rates were constant for at least 1 week. Storage of the release system at ambient conditions up to 6 months or sterilization by means of steam, ethylene oxide exposure, or gamma irradiation did not affect the release properties. It was concluded that this concept for a heparin release system is highly promising to prepare thromboresistant surfaces for various blood contacting devices.
引用
收藏
页码:163 / 176
页数:14
相关论文
共 38 条
[1]   IN-VITRO BIOCOMPATIBILITY EVALUATION OF A HEPARINIZABLE MATERIAL (PUPA), BASED ON POLYURETHANE AND POLY(AMIDO-AMINE) COMPONENTS [J].
ALBANESE, A ;
BARBUCCI, R ;
BELLEVILLE, J ;
BOWRY, S ;
ELOY, R ;
LEMKE, HD ;
SABATINI, L .
BIOMATERIALS, 1994, 15 (02) :129-136
[2]   SURFACE MODIFICATION OF POLYMERIC BIOMATERIALS WITH POLY(ETHYLENE OXIDE), ALBUMIN, AND HEPARIN FOR REDUCED THROMBOGENICITY [J].
AMIJI, M ;
PARK, K .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1993, 4 (03) :217-234
[3]   CHEMICAL AND BIOLOGICAL EVALUATION OF HEPARINIZED POLY(AMIDO-AMINE) GRAFTED POLYURETHANE [J].
AZZUOLI, G ;
BARBUCCI, R ;
BENVENUTI, M ;
FERRUTI, P ;
NOCENTINI, M .
BIOMATERIALS, 1987, 8 (01) :61-66
[4]   STUDY OF HEMODIALYSIS MATERIALS - PHYSICOCHEMICAL AND BIOLOGICAL CHARACTERIZATION OF EVALVA, EVAPA AND HEPARINIZED EVAPA [J].
BARBUCCI, R ;
ALBANESE, A ;
TEMPESTI, F ;
BASZKIN, A ;
ELOY, R ;
WEILL, N ;
MARTUSCELLI, E ;
CIMMINO, S .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (12) :844-849
[5]   RELATIONSHIP BETWEEN RELEASE RATE AND SURFACE CONCENTRATION FOR HEPARINIZED MATERIALS [J].
BASMADJIAN, D ;
SEFTON, MV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (03) :509-518
[6]  
BOKROS J C, 1969, Journal of Biomedical Materials Research, V3, P497, DOI 10.1002/jbm.820030311
[7]  
BROEK AP, 1993, THESIS U TWENTE ENSC
[8]   STRUCTURE AND BIOLOGICAL-ACTIVITY OF HEPARIN [J].
CASU, B .
ADVANCES IN CARBOHYDRATE CHEMISTRY AND BIOCHEMISTRY, 1985, 43 :51-134
[9]  
COLTON C K, 1971, Journal of Biomedical Materials Research, V5, P459, DOI 10.1002/jbm.820050504
[10]  
Comper W.D, 1981, HEPARIN RELATED POLY