Detection of lung tumor movement in real-time tumor-tracking radiotherapy

被引:222
作者
Shimizu, S
Shirato, H
Ogura, S
Akita-Dosaka, H
Kitamura, K
Nishioka, T
Kagei, K
Nishimura, M
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiat Med, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Sch Med, Dept Med, Sapporo, Hokkaido 0608638, Japan
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 51卷 / 02期
关键词
radiotherapy; lung; organ motion; respiratory movement; tumor tracking;
D O I
10.1016/S0360-3016(01)01641-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: External radiotherapy for lung tumors requires reducing the uncertainty due to setup error and organ motion. We investigated the three-dimensional movement of lung tumors through an inserted internal marker using a real-time tumor-tracking system and evaluated the efficacy of this system at reducing the internal margin. Methods and Materials: Four patients with lung cancer were analyzed. A 2.0-mm gold marker was inserted into the tumor. The real-time tumor-tracking system calculates and stores three-dimensional coordinates of the marker 30 times/s. The system can trigger the linear accelerator to irradiate the tumor only when the marker is located within the predetermined "permitted dislocation." The value was set at :+/-1 to +/-3 mm according to the patient's characteristics. We analyzed 10,413-14,893 data sets for each of the 4 patients. The range of marker movement during normal breathing (beam-off period) was compared with that during gated irradiation (beam-on period) by Student's t test. Results: The range of marker movement during the beam-off period was 5.5-10.0 mm in the lateral direction (x), 6.8-15.9 mm in the craniocaudal direction (y) and 8.1-14.6 mm in the ventrodorsal direction (z). The range during the beam-on period was reduced to within 5.3 mm in all directions in all 4 patients. A significant difference was found between the mean of the range during the beam-off period and the mean of the range during the beam-on period in the x (p = 0.007), y (p = 0.025), and z (p = 0.002) coordinates, respectively. Conclusion: The real-time tumor-tracking radiotherapy system was useful to analyze the movement of an internal marker. Treatment with megavoltage X-rays was properly given when the tumor marker moved into the "permitted dislocation" zone from the planned position. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:304 / 310
页数:7
相关论文
共 17 条
[1]  
ICRU, 1999, ICRU REPORT, V62, P3
[2]   A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy [J].
Killoran, JH ;
Kooy, HM ;
Gladstone, DJ ;
Welte, FJ ;
Beard, CJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (01) :213-221
[3]   Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center [J].
Kubo, HD ;
Len, PM ;
Minohara, S ;
Mostafavi, H .
MEDICAL PHYSICS, 2000, 27 (02) :346-353
[4]   A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans [J].
Mageras, GS ;
Kutcher, GJ ;
Leibel, SA ;
Zelefsky, MJ ;
Melian, E ;
Mohan, R ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :333-342
[5]   Respiratory gated irradiation system for heavy-ion radiotherapy [J].
Minohara, S ;
Kanai, T ;
Endo, M ;
Noda, K ;
Kanazawa, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04) :1097-1103
[6]   IRRADIATION SYNCHRONIZED WITH RESPIRATION GATE [J].
OHARA, K ;
OKUMURA, T ;
AKISADA, M ;
INADA, T ;
MORI, T ;
YOKOTA, H ;
CALAGUAS, MJB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (04) :853-857
[7]   A comparison of beam characteristics for gated and nongated clinical x-ray beams [J].
Ramsey, CR ;
Cordrey, IL ;
Oliver, AL .
MEDICAL PHYSICS, 1999, 26 (10) :2086-2091
[8]   A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy [J].
Seiler, PG ;
Blattmann, H ;
Kirsch, S ;
Muench, RK ;
Schilling, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :N103-N110
[9]   High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors [J].
Shimizu, S ;
Shirato, H ;
Aoyama, H ;
Hashimoto, S ;
Nishioka, T ;
Yamazaki, A ;
Kagei, K ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :471-474
[10]   Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy [J].
Shimizu, S ;
Shirato, H ;
Kagei, K ;
Nishioka, T ;
Bo, X ;
Dosaka-Akita, H ;
Hashimoto, S ;
Aoyama, H ;
Tsuchiya, K ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (05) :1127-1133