Chemilummescence microfluidic chip fabricated in PMMA for determination of benzoyl peroxide in flour

被引:27
作者
Liu, W
Zhang, ZJ [1 ]
Yang, L
机构
[1] SW Normal Univ, Inst Analyt Sci, Dept Chem, Chongqing 400715, Peoples R China
[2] Shaanxi Normal Univ, Coll Chem & Mat Sci, Xian 710062, Peoples R China
关键词
microfluidic chip; benzoyl peroxide; chemiluminescence;
D O I
10.1016/j.foodchem.2005.04.005
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A rapid and sensitive chemiluminescence microfluidic chip fabricated in polymethyl methacrylate for determination of benzoyl peroxide in flour is described. The width of the microchannel was 200 mu m and the depth was 100 pin in the chip (50 x 40 x 5 mm). The total length of the microchannel was 67 turn with the detection area of 5 x 5 mm. Benzoyl peroxide can directly oxidize luminol to produce chemiluminescence. Two injectors of double-tee injector and microvalve injector were used. The sampling volume was 0.16 mu l for the double-tee injector and 0.25 mu l for the microvalve injector. The linear range of the benzoyl peroxide concentration was 8 X 10(-7)-1 X 10(-4) g/ml. The detection limit was 4 x 10(-7) g/ml and the R.S.D for eight times is 3.06% for the double-tee injector and 2.41% for the microvalve injector. The proposed method has been successfully applied to the determination of benzoyl peroxide in flour. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:693 / 698
页数:6
相关论文
共 19 条
[1]   SIMULTANEOUS DETERMINATION OF HYDROPEROXIDES OF PHOSPHATIDYLCHOLINE, CHOLESTEROL ESTERS AND TRIACYLGLYCEROLS BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A POSTCOLUMN DETECTION SYSTEM [J].
AKASAKA, K ;
OHRUI, H ;
MEGURO, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (02) :153-159
[2]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[3]  
CAI WH, 2002, HENAN J PREVENT MED, V13, P9
[4]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[5]   Determination of benzoyl peroxide in wheat flour by ion chromatography with precolumn derivatization [J].
Chen, QC ;
Mou, SF ;
Hou, XP ;
Ni, ZM .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (05) :705-716
[6]  
FENNEMA OR, 1985, FOOD CHEM, P629
[7]   Electrokinetic injection techniques in microfluidic chips [J].
Fu, LM ;
Yang, RJ ;
Lee, GB ;
Liu, HH .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :5084-5091
[8]   Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determination [J].
Greenway, GM ;
Nelstrop, LJ ;
Port, SN .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :43-50
[9]   Chemiluminescence μTAS for the determination of atropine and pethidine [J].
Greenwood, PA ;
Merrin, C ;
McCreedy, T ;
Greenway, GM .
TALANTA, 2002, 56 (03) :539-545
[10]   Chemiluminescence detection for a microchip capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Liu, BF ;
Ozaki, M ;
Utsumi, Y ;
Hattori, T ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2003, 75 (01) :36-41