Interfacial instabilities affect microfluidic extraction of small molecules from non-Newtonian fluids

被引:27
作者
Helton, Kristen L. [1 ]
Yager, Paul [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
D O I
10.1039/b709585f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As part of a project to develop an integrated microfluidic biosensor for the detection of small molecules in saliva, practical issues of extraction of analytes from non-Newtonian samples using an H-filter were explored. The H-filter can be used to rapidly and efficiently extract small molecules from a complex sample into a simpler buffer. The location of the interface between the sample and buffer streams is a critical parameter in the function of the H-filter, so fluorescence microscopy was employed to monitor the interface position; this revealed apparently anomalous fluorophore diffusion from the samples into the buffer solutions. Using confocal microscopy to understand the three-dimensional distribution of the fluorophore, it was found that the interface between the non-Newtonian sample and Newtonian buffer was both curved and unstable. The core of the non-Newtonian sample extended into the Newtonian buffer and its position was unstable, producing a fluorescence intensity profile that gave rise to the apparently anomalously fast fluorophore transport. These instabilities resulted from the pairing of rheologically dissimilar fluid streams and were flowrate dependent. We conclude that use of non- Newtonian fluids, such as saliva, in the H-filter necessitates pretreatment to reduce viscoelasticity. The interfacial variation in position, stability and shape caused by the non-Newtonian samples has substantial implications for the use of biological samples for quantitative analysis and analyte extraction in concurrent flow extraction devices.
引用
收藏
页码:1581 / 1588
页数:8
相关论文
共 47 条
[1]  
Balmer R. T., 1978, BIORHEOLOGY, V74, P125
[2]  
BEZAIRE D, 2005, THESIS U WASHINGTON
[3]   Time dependent finite element analysis of the linear stability of viscoelastic flows with interfaces [J].
Bogaerds, ACB ;
Hulsen, MA ;
Peters, GWM ;
Baaijens, FPT .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2003, 116 (01) :33-54
[4]   Biotechnology at low Reynolds numbers [J].
Brody, JP ;
Yager, P ;
Goldstein, RE ;
Austin, RH .
BIOPHYSICAL JOURNAL, 1996, 71 (06) :3430-3441
[5]   Diffusion-based extraction in a microfabricated device [J].
Brody, JP ;
Yager, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 58 (01) :13-18
[6]   ELASTIC INSTABILITY OF THE INTERFACE IN COUETTE-FLOW OF VISCOELASTIC LIQUIDS [J].
CHEN, KP .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 1991, 40 (02) :261-267
[7]   Salivary cortisol on ROCHE Elecsys immunoassay system: pilot biological variation studies [J].
Chiu, SK ;
Collier, CP ;
Clark, AF ;
Wynn-Edwards, KE .
CLINICAL BIOCHEMISTRY, 2003, 36 (03) :211-214
[8]  
Davis S.S., 1971, Rheol. Acta, V10, P28
[9]   Screening and diagnosis of Cushing's syndrome [J].
Findling, JW ;
Raff, H .
ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2005, 34 (02) :385-+
[10]   An investigation of interfacial instabilities in the superposed channel flow of viscoelastic fluids [J].
Ganpule, HK ;
Khomami, B .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 1999, 81 (1-2) :27-69