Modeling envelope statistics of blood and myocardium for segmentation of echocardiographic images

被引:33
作者
Nillesen, Maartje M. [1 ]
Lopata, Richard G. P. [1 ]
Gerrits, Inge H. [1 ]
Kapusta, Livia [2 ]
Thijssen, Johan M. [1 ]
de Korte, Chris L. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Pediat, Clin Phys Lab, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Childrens Heart Ctr, NL-6500 HB Nijmegen, Netherlands
关键词
echocardiography; ultrasound; image segmentation; adaptive filtering; speckle reduction; speckle statistics;
D O I
10.1016/j.ultrasmedbio.2007.10.008
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
The objective of this study was to investigate the use of speckle statistics as a preprocessing step for segmentation of the myocardium in echocardiographic images. Three-dimensional (3D) and biplane image sequences of the left ventricle of two healthy children and one dog (beagle) were acquired. Pixel-based speckle statistics of manually segmented blood and myocardial regions were investigated by fitting various probability density functions (pdf). The statistics of heart muscle and blood could both be optimally modeled by a K-pdf or Gamma-pdf (Kolmogorov-Smirnov goodness-of-fit test). Scale and shape parameters of both distributions could differentiate between blood and myocardium. Local estimation of these parameters was used to obtain parametric images, where window size was related to speckle size (5 x 2 speckles). Moment-based and maximum-likelihood estimators were used. Scale parameters were still able to differentiate blood from myocardium; however, smoothing of edges of anatomical structures occurred. Estimation of the shape parameter required a larger window size, leading to unacceptable blurring. Using these parameters as an input for segmentation resulted in unreliable segmentation. Adaptive mean squares filtering was then introduced using the moment-based scale parameter (sigma(2)/mu) of the Gamma-pdf to automatically steer the two-dimensional (2D) local filtering process. This method adequately preserved sharpness of the edges. In conclusion, a trade-off between preservation of sharpness of edges and goodness-of-fit when estimating local shape and scale parameters is evident for parametric images. For this reason, adaptive filtering outperforms parametric imaging for the segmentation of echocardiographic images.
引用
收藏
页码:674 / 680
页数:7
相关论文
共 25 条
[1]
Multiple resolution Bayesian segmentation of ultrasound images [J].
Ashton, EA ;
Parker, KJ .
ULTRASONIC IMAGING, 1995, 17 (04) :291-304
[2]
ADAPTIVE FILTERING FOR REDUCTION OF SPECKLE IN ULTRASONIC PULSE-ECHO IMAGES [J].
BAMBER, JC ;
DAFT, C .
ULTRASONICS, 1986, 24 (01) :41-44
[3]
SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[4]
NON-RAYLEIGH 1ST-ORDER STATISTICS OF ULTRASONIC BACKSCATTER FROM NORMAL MYOCARDIUM [J].
CLIFFORD, L ;
FITZGERALD, P ;
JAMES, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (06) :487-495
[5]
Conover W. J., 1980, PRACTICAL NONPARAMET
[6]
Modeling the amplitude statistics of ultrasonic images [J].
Eltoft, T .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (02) :229-240
[7]
Method for estimating the parameters of the K distribution [J].
Iskander, DR ;
Zoubir, AM ;
Boashash, B .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1999, 47 (04) :1147-1151
[8]
GENERALIZED K-DISTRIBUTION - A STATISTICAL-MODEL FOR WEAK SCATTERING [J].
JAKEMAN, E ;
TOUGH, RJA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (09) :1764-1772
[9]
MODEL FOR NON-RAYLEIGH SEA ECHO [J].
JAKEMAN, E ;
PUSEY, PN .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1976, 24 (06) :806-814
[10]
Kolár R, 2004, RADIOENGINEERING, V13, P8