Dynamic behavior of ultra-thin polymer films deposited on surface acoustical wave devices

被引:12
作者
Ahuja, A [1 ]
James, DL [1 ]
Narayan, R [1 ]
机构
[1] Texas Tech Univ, Lubbock, TX 79409 USA
关键词
SAW device; polymer; gas sensor; chemical sensor; sorption;
D O I
10.1016/S0924-4247(98)00236-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports the experimental results for polymer-coated surface acoustic wave (SAW) that were exposed to various gases (carbon dioxide, methane, ethane). The polymers used to coat the SAW devices were polycarbonate (PC; glassy), polyisobutylene (PIB; rubbery), and polydimethylsiloxane (PDMS; most rubbery). It was observed that the direction of the frequency shift of the SAW delay line oscillator for the SAW filters coated with PC and PIE could be described from existing work by Wohltjen [H. Wohltjen, Mechanism of operation and design considerations for surface acoustic wave device vapor sensors, Sensors and Actuators A 5 (1984) 307-325] in which the modulus terms and the electrical terms are insignificant compared to the mass loading terms. However, for the PDMS-coated SAW this was not the case. In every experiment performed. the frequency shift was positive, exactly opposite of what was predicted by the Wohltjen's equation for acoustically thin, perfectly elastic films. It is felt that operation at high frequencies causes changes in the oscillation frequency due to changes in the modulus term in Wohltjen's equation to be comparable to the change in frequency due to the mass loading (Delta hp') term. This is especially relevant if the solubility of the penetrant gases is low. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:234 / 241
页数:8
相关论文
共 20 条
[1]  
AHUJA A, 1996, THESIS TEXAS TECH U
[2]  
BOASC D, 1990, J APPL POLYM SCI, V40, P135
[3]  
Clarson S. J., 1993, Siloxane Polymers
[4]  
Ferry D.J., 1980, Viscoelastic Properties of Polymers, V3e
[5]   SOLUBILITY INTERACTIONS AND THE DESIGN OF CHEMICALLY SELECTIVE SORBENT COATINGS FOR CHEMICAL SENSORS AND ARRAYS [J].
GRATE, JW ;
ABRAHAM, MH .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 3 (02) :85-111
[6]   DETERMINATION OF PARTITION-COEFFICIENTS FROM SURFACE ACOUSTIC-WAVE VAPOR SENSOR RESPONSES AND CORRELATION WITH GAS-LIQUID CHROMATOGRAPHIC PARTITION-COEFFICIENTS [J].
GRATE, JW ;
SNOW, A ;
BALLANTINE, DS ;
WOHLTJEN, H ;
ABRAHAM, MH ;
MCGILL, RA ;
SASSON, P .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :869-875
[7]   THE PREDOMINANT ROLE OF SWELLING-INDUCED MODULUS CHANGES OF THE SORBENT PHASE IN DETERMINING THE RESPONSES OF POLYMER-COATED SURFACE ACOUSTIC-WAVE VAPOR SENSORS [J].
GRATE, JW ;
KLUSTY, M ;
MCGILL, RA ;
ABRAHAM, MH ;
WHITING, G ;
ANDONIANHAFTVAN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :610-624
[8]   SORPTION AND TRANSPORT OF VARIOUS GASES IN POLYCARBONATE [J].
KOROS, WJ ;
CHAN, AH ;
PAUL, DR .
JOURNAL OF MEMBRANE SCIENCE, 1977, 2 (02) :165-190
[9]   SURFACE ACOUSTIC-WAVE RESPONSE TO CHANGES IN VISCOELASTIC FILM PROPERTIES [J].
MARTIN, SJ ;
FRYE, GC .
APPLIED PHYSICS LETTERS, 1990, 57 (18) :1867-1869
[10]   DYNAMICS AND RESPONSE OF POLYMER-COATED SURFACE-ACOUSTIC-WAVE DEVICES - EFFECT OF VISCOELASTIC PROPERTIES AND FILM RESONANCE [J].
MARTIN, SJ ;
FRYE, GC ;
SENTURIA, SD .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2201-2219