Real-time quantification and display of skin radiation during coronary angiography and intervention

被引:80
作者
den Boer, A [1 ]
de Feijter, PJ [1 ]
Serruys, PW [1 ]
Roelandt, JRTC [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr BD 428, NL-3000 GR Rotterdam, Netherlands
关键词
radiography; catheterization; dosage;
D O I
10.1161/hc4001.097057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Radiographically guided investigations may be associated with excessive radiation exposure, which may cause skin injuries. The purpose of this study was to develop and test a system that measures in real time the dose applied to cacti 1-cm(2) area of skin, taking into account the movement of the x-ray source and changes in the beam characteristics. The goal of such a system is to help prevent high doses that might cause skin injury. Methods and Results-The entrance point, beani size, and dose at the skin of the patient were calculated by use of the geometrical settings of gantry, investigation table, and x-ray beam and an ionization chamber. The data are displayed graphically. Three hundred twenty-two sequential cardiac investigations in adult patients were analyzed. The mean peak entrance dose per investigation was 0.475 Gy to a mean skin area of 8.2 cm(2). The cumulative KERMA-area product per investigation was 52.2 Gy/cm(2) (25.4 to 99.2 Gy/cm(2)), and the mean entrance beam size at the skin was 49.2 cm(2). Twenty-eight percent of the patients (90/322) received a maximum dose of <1 Gy to a small skin area (approximate to6 cm(2)), and 13.5% of the patients (42/322) received a maximum dose of >2 Gy. Conclusions-Monitoring of the dose distribution at the skin will alert the operator to the development of high-dose areas; by use of other gantry settings with nonoverlapping entrance fields, different generator settings, and extra collimation, skin lesion can be avoided.
引用
收藏
页码:1779 / 1784
页数:6
相关论文
共 30 条
  • [1] BAKALYAR DM, 1997, CATHET CARDIOVASC DI, V2, P121
  • [2] BALTER S, 1993, CATHET CARDIOVASC DI, V4, P277
  • [3] RADIATION EXPOSURE DURING RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR CONNECTIONS
    CALKINS, H
    NIKLASON, L
    SOUSA, J
    ELATASSI, R
    LANGBERG, J
    MORADY, F
    [J]. CIRCULATION, 1991, 84 (06) : 2376 - 2382
  • [4] RADIATION EXPOSURE TO PATIENTS UNDERGOING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    CASCADE, PN
    PETERSON, LE
    WAJSZCZUK, WJ
    MANTEL, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (09) : 996 - 997
  • [5] REDUCTION OF RADIATION EXPOSURE WHILE MAINTAINING HIGH-QUALITY FLUOROSCOPIC IMAGES DURING INTERVENTIONAL CARDIOLOGY USING NOVEL X-RAY TUBE TECHNOLOGY WITH EXTRA BEAM FILTERING
    DENBOER, A
    DEFEYTER, PJ
    HUMMEL, WA
    KEANE, D
    ROELANDT, JRTC
    [J]. CIRCULATION, 1994, 89 (06) : 2710 - 2714
  • [6] Radiodermatitis following cardiac catheterization
    DIncan, M
    Roger, H
    leBouedec, MCF
    Souteyrand, P
    [J]. ARCHIVES OF DERMATOLOGY, 1997, 133 (02) : 242 - 243
  • [7] RADIATION-DOSES AND SOMATIC RISK TO PATIENTS DURING CARDIAC RADIOLOGICAL PROCEDURES
    FAULKNER, K
    LOVE, HG
    SWEENEY, JK
    BARDSLEY, RA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (700) : 359 - 363
  • [8] *FDA, 1994, FOOD DRUG ADM MED B, P24
  • [9] *FDA, 1995, IMP INF PHYS HEALTHC
  • [10] Food and Drug Administration, 1994, PUBL HLTH ADV AV SER