Systematic errors in the measurement of adsorption isotherms by frontal analysis - Impact of the choice of column hold-up volume, range and density of the data points

被引:42
作者
Gritti, F
Guiochon, G
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
基金
美国国家科学基金会;
关键词
adsorption isotherm; frontal analysis; systematic errors; column hold-up volume; data acquisition; isotherm modeling; overloaded band profiles;
D O I
10.1016/j.chroma.2005.08.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Besides the accuracy and the precision of the measurements of the data points, several important parameters affect the accuracy of the adsorption isotherms that are derived from the data acquired by frontal analysis (FA). The influence of these parameters is discussed. First, the effects of the width of the concentration range within which the adsorption data are measured and of the distribution of the data points in this range are investigated. Systematic elimination of parts of the data points before the calculation of the nonlinear regression of the data to the model illustrates the importance of the numbers of data points (1) within the linear range and (2) at high concentrations. The influence of the inaccuracy of the estimate of the column hold-up volume on each adsorption data point, on the selection of the isotherm model, and on the best estimates of the adsorption isotherm parameters is also stressed. Depending on the method used to measure it, the hold-up time can vary by more than 10%. The high concentration part of the adsorption isotherm is particularly sensitive to errors made on t(0,exp) and as a result, when the isotherm follows bi-Langmuir isotherm behavior, the equilibrium constant of the low-energy sites may change by a factor 2. This study shows that the agreement between calculated and experimental overloaded band profiles is a necessary condition to validate the choice of an adsorption model and the calculation of its numerical parameters but that this condition is not sufficient. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 115
页数:18
相关论文
共 30 条
[1]   CONTINUOUS FLOW SYSTEMS - DISTRIBUTION OF RESIDENCE TIMES [J].
DANCKWERTS, PV .
CHEMICAL ENGINEERING SCIENCE, 1953, 2 (01) :1-13
[2]   THE MOLECULAR MECHANISM OF RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
DORSEY, JG ;
DILL, KA .
CHEMICAL REVIEWS, 1989, 89 (02) :331-346
[3]   Adsorption isotherms of nonionic surfactants in SBA-15 measured by micro-column chromatography [J].
Findenegg, G. H. ;
Eltekov, A. Y. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) :236-240
[4]  
FLORY P.J., PRINCIPLES POLYM CHE
[5]  
GOTMAR G, 2002, THESIS UPSALLA U UPS
[6]   Adsorption mechanism in RPLC. Effect of the nature of the organic modifier [J].
Gritti, F ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4257-4272
[7]   Influence of the pressure on the properties of chromatographic columns III.: Retention volume of thiourea, hold-up volume, and compressibility of the C18-bonded layer [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :117-126
[8]   Influence of pressure on the properties of chromatographic columns - II. The column hold-up volume [J].
Gritti, F ;
Martin, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1070 (1-2) :13-22
[9]   Influence of the pressure on the properties of chromatographic columns - I. Measurement of the compressibility of methanol-water mixtures on a mesoporous silica adsorbent [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1070 (1-2) :1-12
[10]   Effect of the surface heterogeneity of the stationary phase on the range of concentrations for linear chromatography [J].
Gritti, F ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :1020-1030