Tumor Ablation with Irreversible Electroporation

被引:353
作者
Al-Sakere, Bassim [1 ,2 ]
Andre, Franck [1 ,2 ]
Bernat, Claire [1 ,2 ]
Connault, Elisabeth [1 ,2 ]
Opolon, Paule [1 ,2 ]
Davalos, Rafael V. [3 ]
Rubinsky, Boris [4 ,5 ,6 ,7 ]
Mir, Lluis M. [1 ,2 ]
机构
[1] Inst Gustave Roussy, CNRS, UMR 8121, Villejuif, France
[2] Univ Paris Sud, UMR 8121, Villejuif, France
[3] Virginia Tech Wake Forest Univ, Sch Biomed Engn & Sci, Blacksburg, VA USA
[4] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
[5] Univ Calif Berkeley, Grad Program Biophys, Berkeley, CA 94720 USA
[6] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[7] Hebrew Univ Jerusalem, Sch Comp Sci & Engn, Ctr Bioengn Serv Humanity & Soc, Jerusalem, Israel
来源
PLOS ONE | 2007年 / 2卷 / 11期
基金
美国国家卫生研究院;
关键词
D O I
10.1371/journal.pone.0001135
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report the first successful use of irreversible electroporation for the minimally invasive treatment of aggressive cutaneous tumors implanted in mice. Irreversible electroporation is a newly developed non-thermal tissue ablation technique in which certain short duration electrical fields are used to permanently permeabilize the cell membrane, presumably through the formation of nanoscale defects in the cell membrane. Mathematical models of the electrical and thermal fields that develop during the application of the pulses were used to design an efficient treatment protocol with minimal heating of the tissue. Tumor regression was confirmed by histological studies which also revealed that it occurred as a direct result of irreversible cell membrane permeabilization. Parametric studies show that the successful outcome of the procedure is related to the applied electric field strength, the total pulse duration as well as the temporal mode of delivery of the pulses. Our best results were obtained using plate electrodes to deliver across the tumor 80 pulses of 100 mu s at 0.3 Hz with an electrical field magnitude of 2500 V/cm. These conditions induced complete regression in 12 out of 13 treated tumors, (92%), in the absence of tissue heating. Irreversible electroporation is thus a new effective modality for non-thermal tumor ablation.
引用
收藏
页数:8
相关论文
共 47 条
[1]   A study of the immunological response to tumor ablation with irreversible Electroporation [J].
Al-Sakere, B. ;
Bernat, C. ;
Andr, F. ;
Connault, E. ;
Opolon, P. ;
Davalos, R. V. ;
Mir, L. M. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2007, 6 (04) :301-305
[2]   DNA electrotransfer:: its principles and an updated review of its therapeutic applications [J].
André, F ;
Mir, LM .
GENE THERAPY, 2004, 11 (Suppl 1) :S33-S42
[3]  
BECKER SM, 2006, ASME, V128, P76
[4]   Diverse effects of nanosecond pulsed electric fields on cells and tissues [J].
Beebe, SJ ;
White, J ;
Blackmore, PF ;
Deng, YP ;
Somers, K ;
Schoenbach, KH .
DNA AND CELL BIOLOGY, 2003, 22 (12) :785-796
[5]   EVOLUTION OF CELL-MEDIATED ANTITUMOR IMMUNITY IN MICE BEARING A SYNGENIC CHEMICALLY INDUCED TUMOR - INFLUENCE OF TUMOR GROWTH, SURGICAL REMOVAL AND TREATMENT WITH IRRADIATED TUMOR-CELLS [J].
BELEHRAD.J ;
BARSKI, G ;
THONIER, M .
INTERNATIONAL JOURNAL OF CANCER, 1972, 27 (54) :461-+
[6]  
BELEHRADEK M, 1993, CANCER-AM CANCER SOC, V72, P3694, DOI 10.1002/1097-0142(19931215)72:12<3694::AID-CNCR2820721222>3.0.CO
[7]  
2-2
[8]   EVALUATION OF ACCURACY OF A THEORETICAL-MODEL FOR PREDICTING THE NECROSED TISSUE VOLUME DURING FOCUSED ULTRASOUND SURGERY [J].
DAMIANOU, CA ;
HYNYNEN, K ;
FAN, XB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (02) :182-187
[9]  
Davalos R, 2000, MICROSCALE THERM ENG, V4, P147
[10]   Theoretical analysis of the thermal effects during in vivo tissue electroporation [J].
Davalos, RV ;
Rubinsky, B ;
Lir, LM .
BIOELECTROCHEMISTRY, 2003, 61 (1-2) :99-107