Retinal status analysis method based on feature extraction and quantitative grading in OCT images

被引:24
作者
Fu, Dongmei [1 ]
Tong, Hejun [1 ]
Zheng, Shuang [1 ]
Luo, Ling [2 ]
Gao, Fulin [2 ]
Minar, Jiri [3 ]
机构
[1] Univ Sci & Technol Beijing, Sch Automat & Elect Engn, Xueyuan Rd 30, Beijing, Peoples R China
[2] 306th Hosp Peoples Liberat Army, Beijing, Peoples R China
[3] Brno Univ Technol, Fac Elect Engn & Commun, Dept Telecommun, Brno, Czech Republic
基金
中国国家自然科学基金;
关键词
Retinal OCT images; Image processing; Morphological characterization; Feature quantification; Grade evaluation; OPTICAL COHERENCE TOMOGRAPHY; MACULAR PATHOLOGY DIAGNOSIS; SPECKLE NOISE-REDUCTION; SEGMENTATION; THICKNESS; LAYERS; TEXTURE; EYES;
D O I
10.1186/s12938-016-0206-x
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Optical coherence tomography (OCT) is widely used in ophthalmology for viewing the morphology of the retina, which is important for disease detection and assessing therapeutic effect. The diagnosis of retinal diseases is based primarily on the subjective analysis of OCT images by trained ophthalmologists. This paper describes an OCT images automatic analysis method for computer-aided disease diagnosis and it is a critical part of the eye fundus diagnosis. Methods: This study analyzed 300 OCT images acquired by Optovue Avanti RTVue XR (Optovue Corp., Fremont, CA). Firstly, the normal retinal reference model based on retinal boundaries was presented. Subsequently, two kinds of quantitative methods based on geometric features and morphological features were proposed. This paper put forward a retinal abnormal grading decision-making method which was used in actual analysis and evaluation of multiple OCT images. Results: This paper showed detailed analysis process by four retinal OCT images with different abnormal degrees. The final grading results verified that the analysis method can distinguish abnormal severity and lesion regions. This paper presented the simulation of the 150 test images, where the results of analysis of retinal status showed that the sensitivity was 0.94 and specificity was 0.92. The proposed method can speed up diagnostic process and objectively evaluate the retinal status. Conclusions: This paper aims on studies of retinal status automatic analysis method based on feature extraction and quantitative grading in OCT images. The proposed method can obtain the parameters and the features that are associated with retinal morphology. Quantitative analysis and evaluation of these features are combined with reference model which can realize the target image abnormal judgment and provide a reference for disease diagnosis.
引用
收藏
页数:18
相关论文
共 36 条
[1]
Optical Coherence Tomography Retinal Thickness and Volume Measurements in X-Linked Retinoschisis [J].
Andreoli, Michael T. ;
Lim, Jennifer I. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (03) :567-573
[2]
Improved adaptive complex diffusion despeckling filter [J].
Bernardes, Rui ;
Maduro, Cristina ;
Serranho, Pedro ;
Araujo, Aderito ;
Barbeiro, Silvia ;
Cunha-Vaz, Jose .
OPTICS EXPRESS, 2010, 18 (23) :24048-24059
[3]
A review of image denoising algorithms, with a new one [J].
Buades, A ;
Coll, B ;
Morel, JM .
MULTISCALE MODELING & SIMULATION, 2005, 4 (02) :490-530
[4]
Automated drusen segmentation and quantification in SD-OCT images [J].
Chen, Qiang ;
Leng, Theodore ;
Zheng, Luoluo ;
Kutzscher, Lauren ;
Ma, Jeffrey ;
de Sisternes, Luis ;
Rubin, Daniel L. .
MEDICAL IMAGE ANALYSIS, 2013, 17 (08) :1058-1072
[5]
Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation [J].
Chiu, Stephanie J. ;
Li, Xiao T. ;
Nicholas, Peter ;
Toth, Cynthia A. ;
Izatt, Joseph A. ;
Farsiu, Sina .
OPTICS EXPRESS, 2010, 18 (18) :19413-19428
[6]
Image denoising by sparse 3-D transform-domain collaborative filtering [J].
Dabov, Kostadin ;
Foi, Alessandro ;
Katkovnik, Vladimir ;
Egiazarian, Karen .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2007, 16 (08) :2080-2095
[7]
Denoising optical coherence tomography using second order total generalized variation decomposition [J].
Duan, Jinming ;
Lu, Wenqi ;
Tench, Christopher ;
Gottlob, Irene ;
Proudlock, Frank ;
Samani, Niraj Nilesh ;
Bai, Li .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 24 :120-127
[8]
Normal Macular Thickness Measurements Using Optical Coherence Tomography in Healthy Eyes of Adult Chinese Persons: The Handan Eye Study [J].
Duan, Xin Rong ;
Liang, Yuan Bo ;
Friedman, David S. ;
Sun, Lan Ping ;
Wong, Tien Yin ;
Tao, Qiu Shan ;
Bao, Lingzhi ;
Wang, Ning Li ;
Wang, Jie Jin .
OPHTHALMOLOGY, 2010, 117 (08) :1585-1594
[9]
Graph-Based Multi-Surface Segmentation of OCT Data Using Trained Hard and Soft Constraints [J].
Dufour, Pascal A. ;
Ceklic, Lala ;
Abdillahi, Hannan ;
Schroeder, Simon ;
De Dzanet, Sandro ;
Wolf-Schnurrbusch, Ute ;
Kowal, Jens .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (03) :531-543
[10]
Spectral Domain Optical Coherence Tomography Imaging of Drusen in Nonexudative Age-Related Macular Degeneration [J].
Gregori, Giovanni ;
Wang, Fenghua ;
Rosenfeld, Philip J. ;
Yehoshua, Zohar ;
Gregori, Ninel Z. ;
Lujan, Brandon J. ;
Puliafito, Carmen A. ;
Feuer, William J. .
OPHTHALMOLOGY, 2011, 118 (07) :1373-1379