Design and validation of a high-flow personal sampler for PM2.5

被引:25
作者
Adams, HS [1 ]
Kenny, LC [1 ]
Nieuwenhuijsen, MJ [1 ]
Colvile, RN [1 ]
Gussman, RA [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, TH Huxley Sch Environm Earth Sci & Engn, London SW7 2BP, England
来源
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY | 2001年 / 11卷 / 01期
关键词
foam samplers; particles; personal exposure; personal sampler; PM2.5;
D O I
10.1038/sj.jea.7500152
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A high-flow personal sampler (HFPS) for airborne particulate matter has been developed and fully characterised, and validation tests have been carried out. The sampler is a low-cost gravimetric instrument designed to collect particulate matter with a 50% cut point at 2.5 mum aerodynamic equivalent diameter (PM2.5), where size selection is achieved by the use of porous polyurethane foam. Development of a porous foam selector was chosen over a cyclone or impactor due to the lightweight, low-cost, and compact design that could be achieved. The sampler flow rate of 16 l/min is achieved using a portable, flow-controlled pump; this flow rate is far higher than that of conventional personal samplers and the HFPS can therefore be used for personal sampling in the ambient environment over short sampling periods of much less than 24 h. The HFPS is currently being used in a study of particle exposure of urban transport users (cyclists, car drivers, bus and Underground rail passengers) where personal sampling over short time periods representing typical commuter journey times is required. The HFPS was fully characterised in chamber studies with a TSI aerodynamic particle sizer (APS). The sampler was then validated against a co-located U.S. EPA Federal Reference PM2.5 Well impactor Ninety Six (WINS) and a KTL cyclone, and parallel testing was performed. Initial testing showed some penetration of particles through the porous foam structure; applying an oil coating to the foam eliminated this problem. Chamber testing was carried out on a number of different selector prototypes, with the final design giving a 50% penetration diameter (i.e., d(50)) of 2.4 mum at 16 l/min. The new sampler exhibited good agreement in three sets of co-located tests with established samplers, and parallel testing showed excellent agreement between paired HFPS samplers.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 21 条
[1]  
Aitken R. J., 1993, APPL OCCUP ENV HYG, V8, P363
[2]  
Chen CC, 1998, AM IND HYG ASSOC J, V59, P766, DOI 10.1202/0002-8894(1998)059<0766:DORASU>2.0.CO
[3]  
2
[4]  
*COMEAP, 1998, QUAL EFF AIR POLL HL
[5]  
*DETR, 1999, 178274 DETR AQ
[6]   A GENERAL EQUATION FOR AEROSOL ASPIRATION BY THIN-WALLED SAMPLING PROBES IN CALM AND MOVING AIR [J].
GRINSHPUN, S ;
WILLEKE, K ;
KALATOOR, S .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (09) :1459-1470
[7]  
Kenney LC, 2000, AEROSOL SCI TECH, V32, P613
[8]  
Kenny L., 1997, 11 ANN C AER SOC P M, P127
[9]   Characterization and modelling of a family of cyclone aerosol preseparators [J].
Kenny, LC ;
Gussman, RA .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (04) :677-688
[10]   The adaptation of existing personal inhalable aerosol samplers for bioaerosol sampling [J].
Kenny, LC ;
Stancliffe, JD ;
Crook, B ;
Stagg, S ;
Griffiths, WD ;
Stewart, IW ;
Futter, SJ .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1998, 59 (12) :831-841