Diagnostic performance of a computer-based ECG rhythm algorithm

被引:62
作者
Poon, K
Okin, PM
Kligfield, P [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Med, Div Cardiol, New York, NY 10021 USA
[2] Cornell Univ, Cornell Ctr, New York Presbyterian Hosp, New York, NY 10021 USA
关键词
algorithm; computer; cardiac rhythm; sensitivity; specificity;
D O I
10.1016/j.jelectrocard.2005.01.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We examined the accuracy of computer-based rhythm interpretation from one electrocardiograph manufacturer (GE Healthcare Technologies MUSE software 005C) in 4297 consecutive recordings in a university hospital setting. Overreading was performed by either of 2 experienced cardiologists, and all disagreements with the initial computer rhythm statement were reviewed by the second cardiologist to achieve physician consensus used as the "gold standard" for rhythm diagnosis. Overall, 13.2% (565/4297) of computer-based rhythm statements required revision, but excluding tracings with pacemakers, the revision rate was 7.8% (307/3954), including 3.8% involving the primary rhythm diagnosis and 3.9% involving definition of ectopic complexes. The false-negative rate for sinus rhythm was only 1.3%, but a computer diagnosis of sinus rhythm was incorrect in 9.9% of other rhythms. The false-negative rate for atrial fibrillation was 9.2%, whereas a computer diagnosis of atrial fibrillation was incorrect in 1.1% of other rhythms, including sinus. Computer diagnosis of paced rhythms remains problematic, and physician overreading to correct computer-based electrocardiogram rhythm diagnoses remains mandatory. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 30 条
[1]  
[Anonymous], ANN N Y ACAD SCI
[2]  
[Anonymous], P ENG FDN C
[3]   METHOD FOR EVALUATING COMPUTER-PROGRAMS FOR ELECTROCARDIOGRAPHIC INTERPRETATION .2. APPLICATION TO VERSION-D OF PHS PROGRAM AND MAYO-CLINIC-PROGRAM OF 1968 [J].
BAILEY, JJ ;
ITSCOITZ, SB ;
GRAUER, LE ;
HIRSHFELD, JW ;
HORTON, MR .
CIRCULATION, 1974, 50 (01) :80-87
[4]   METHOD FOR EVALUATING COMPUTER-PROGRAMS FOR ELECTROCARDIOGRAPHIC INTERPRETATION .1. APPLICATION TO EXPERIMENTAL IBM PROGRAM OF 1971 [J].
BAILEY, JJ ;
ITSCOITZ, SB ;
HIRSHFELD, JW ;
GRAUER, LE ;
HORTON, MR .
CIRCULATION, 1974, 50 (01) :73-79
[5]   METHOD FOR EVALUATING COMPUTER-PROGRAMS FOR ELECTROCARDIOGRAPHIC INTERPRETATION .3. REPRODUCIBILITY TESTING AND SOURCES OF PROGRAM ERRORS [J].
BAILEY, JJ ;
HORTON, M ;
ITSCOITZ, SB .
CIRCULATION, 1974, 50 (01) :88-93
[6]   The impact of computer-assisted test interpretation on physician decision making: The case of electrocardiograms [J].
Brailer, DJ ;
Kroch, E ;
Pauly, MV .
MEDICAL DECISION MAKING, 1997, 17 (01) :80-86
[7]   SURVEY OF COMPUTER-ASSISTED ELECTROCARDIOGRAPHY IN THE UNITED-STATES [J].
DRAZEN, E ;
MANN, N ;
BORUN, R ;
LAKS, M ;
BERSEN, A .
JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 :S98-S104
[8]   Enhanced rhythm analysis for resting ECG using spectral and time-domain techniques [J].
Farrell, RM ;
Xue, JQ ;
Young, BJ .
COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 :733-736
[9]  
FLORO J, 1983, P 1983 ENG FDN C ECG, P11
[10]  
GRAUER K, 1987, J FAM PRACTICE, V24, P39