Assessment of microbial involvement in the elevation of copper levels in drinking water

被引:29
作者
Dutkiewicz, C [1 ]
Fallowfield, H [1 ]
机构
[1] Flinders Univ S Australia, Flinders Med Ctr, Sch Med, Dept Clin Pharmacol,Environm Hlth Unit, Adelaide, SA 5001, Australia
关键词
D O I
10.1046/j.1365-2672.1998.853567.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A Study Of bacterial populations in metropolitan Adelaide domestic reticulation pipes was conducted to investigate a possible link between copper in drinking water and biofilms. Biofilm densities from cold water copper pipes at 10 sample sites were measured by viable cell counts. The range detected was from <2 x 10(1) to 3.25 x 10(7) cfu cm(-2). Five isolates were-selected for further experiments as they represented a range of responses to solvated copper and relative tendency for adhesion on glass slides. Drinking water supplied to the Adelaide Hills is high in total organic carbon (TOC; 22.57 mg C l(-1)) and has a negative Langelier Index (LI; - 1.16), whereas Adelaide metropolitan water undergoes filtration and has both a lower TOC and LI (10.72 mg C l(-1), LI, -0.49). Copper coupons were exposed to biofilm isolates (24 h), washed and resuspended in Adelaide metropolitan and Adelaide Hills mater. Copper coupons not exposed to biofilm isolates were suspended in respective waters as a control. After 5 d of incubation, the copper content of Adelaide Hills water (4.71 +/- 0.87 mg Cu l(-1)), in which the copper coupons were suspended, consistently exceeded values obtained in the metropolitan Adelaide water (1.17 +/- 0.249 mg Cu l(-1)). The concentration of copper in the Adelaide Hills water was influenced by the bacterial species forming the biofilm on the coupon, with Agrobacterium sp. producing significantly higher levels of soluble copper than the control, The experiments reported here indicate that the suspended organic carbon, the aggressivity of the water and the biofilm may independently or synergistically increase the dissolution of copper from pipes into drinking water.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 14 条
[1]   CORROSION BEHAVIOR OF ANNEALED AND HARD-DRAWN COPPER IN SOFT TAP WATER [J].
ALKHARAFI, FM ;
SHALABY, HM .
CORROSION, 1995, 51 (06) :469-481
[2]   LABORATORY-BASED MODEL OF MICROBIOLOGICALLY INDUCED CORROSION OF COPPER [J].
BREMER, PJ ;
GEESEY, GG .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (07) :1956-1962
[3]  
BUCHANAN SD, 1995, EVALUATING GASTROINT
[4]  
Chen Guo Nan, 1994, American Journal of Enology and Viticulture, V45, P305
[5]   ACUTE COPPER SULFATE POISONING [J].
CHUTTANI, HK ;
GUPTA, PS ;
GULATI, S ;
GUPTA, DN .
AMERICAN JOURNAL OF MEDICINE, 1965, 39 (05) :849-+
[6]  
EDWARDS M, 1994, J AM WATER WORKS ASS, V86, P74
[7]  
FISCHER W, 1992, WERKST KORROS, V43, P56
[8]  
KEEVIL CW, 1989, RECENT ADV MICROBIAL, P151
[9]   MECHANISM OF INITIAL EVENTS IN SORPTION OF MARINE BACTERIA TO SURFACES [J].
MARSHALL, KC ;
STOUT, R ;
MITCHELL, R .
JOURNAL OF GENERAL MICROBIOLOGY, 1971, 68 (NOV) :337-&