Effect of insulator environment on thermal ageing estimations for ethylene propylene rubber insulated nuclear power plant cables

被引:7
作者
Alshaketheep, Tariq [1 ]
Murakami, Kenta [2 ]
Sekimura, Naoto [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Nucl Engn & Management, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[2] Univ Tokyo, Nucl Profess Sch, Sch Engn, 2-22 Shirakata Shirane, Tokai, Ibaraki 3191188, Japan
关键词
cable; insulator degradation; ethylene propylene rubber; elongation at break; accelerated thermal ageing; environmental qualification; ageing management; DEGRADATION;
D O I
10.1080/00223131.2015.1108881
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
070305 [高分子化学与物理]; 080810 [电力电子与电能变换];
摘要
Thermal ageing estimations merely focus on the degradation of cable insulator materials without considering their arrangement within the cable structure, by surrounding jacket or colorant pigments. This study reconsidered thermal ageing estimations based on the insulator elongation at break (EAB) degradation progress for flame retardant ethylene propylene rubber (FR-EPR) insulators within the whole cable structure. FR-EPR insulators were aged using two methods. In the first method, the insulators were heated, including jacket material at 125 degrees C, 150 degrees C, and 160 degrees C for 2208, 336, and 264h, respectively. In the second method, the insulators were heated without jacket at 125 degrees C for 3480h, and at 160 degrees C for 264h. It was expected that the EAB degradation progress would be more severe when the FR-EPR insulators were aged without jacket. However, the results contradicted previous expectations, and the special heat-resistant polyvinyl chloride jacket accelerated the EAB degradation. In addition, the black FR-EPR insulators showed values that deviated from the predictions for the activation energy (E-a) and equivalent times compared to the white and red insulators due to the use of carbon black as a pigment. The reduced equivalent times for thermally aged FR-EPR insulators with jacket in this study were evident compared with the current degradation database for FR-EPR insulators degraded without jacket.
引用
收藏
页码:1366 / 1370
页数:5
相关论文
共 17 条
[1]
Alonso J, 2012, NPT36 IAEA
[2]
Alshaketheep T, 2015, E J ADV MAINT, V7, P102
[3]
Anandakumaran A, 2000, IAEATECDOC1188, V1
[4]
Lifetime predictions for semi-crystalline cable insulation materials: I. Mechanical properties and oxygen consumption measurements on EPR materials [J].
Gillen, K. T. ;
Bernstein, R. ;
Clough, R. L. ;
Celina, M. .
POLYMER DEGRADATION AND STABILITY, 2006, 91 (09) :2146-2156
[5]
Hawkins W.L., 1959, J Appl Polym Sci, V1, P37, DOI [10.1002/app.1959.070010107, DOI 10.1002/APP.1959.070010107]
[6]
Correlation between mechanical and electrical properties for assessing the degradation of ethylene propylene rubber cables used in nuclear power plants [J].
Hsu, Y. T. ;
Chang-Liao, K. S. ;
Wang, T. K. ;
Kuo, C. T. .
POLYMER DEGRADATION AND STABILITY, 2007, 92 (07) :1297-1303
[7]
Monitoring the moisture-related degradation of ethylene propylene rubber cable by electrical and SEM methods [J].
Hsu, Y. T. ;
Chang-Liao, K. S. ;
Wang, T. K. ;
Kuo, C. T. .
POLYMER DEGRADATION AND STABILITY, 2006, 91 (10) :2357-2364
[8]
International Electrotechnical Commission, 2012, 625823 IEC
[9]
Japan Nuclear Energy Safety Organization, 2009, JNESSS050102
[10]
Comparison of cable ageing [J].
Placek, Vit ;
Kohout, Tomas .
RADIATION PHYSICS AND CHEMISTRY, 2010, 79 (03) :371-374