Optimization of seawater RO systems design

被引:179
作者
Wilf, M [1 ]
Bartels, C [1 ]
机构
[1] Hydranaut, Oceanside, CA USA
关键词
seawater reverse osmosis; power recovery; boron reduction;
D O I
10.1016/j.desal.2004.06.206
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The paper describes the configuration and operating parameters of current large seawater desalination systems. Major advances of RO seawater desalination technology that lead to a remarkable decrease of desalted water costs are evaluated. Process improvements that enable compliance with more stringent requirements of permeate water quality are discussed. Results of field tests conducted to demonstrate a new process approach are described. Some examples of process optimization resulting in lower power consumption and more efficient system operation are presented.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 6 条
[1]  
Bray Donald T., 1977, U. S. Patent, Patent No. [4046685, 4,046,685]
[2]   Optimization of boron removal in old and new SWRO systems [J].
Glueckstern, P ;
Priel, M .
DESALINATION, 2003, 156 (1-3) :219-228
[3]  
GLUECKSTERN P, 2002, P EDS C TOUL
[4]  
IWAHORI H, 2003, IDA C BAH
[5]  
PEARCE G, 2003, P IDA C BAH
[6]  
STEVENS L, 2003, P IDA C BAH