A stereotactic radiation therapy device for retinoblastoma using a noncircular collimator and intensity filter

被引:8
作者
Cormack, RA [1 ]
Kooy, HM
Bellerive, MR
Loeffler, JS
Petersen, RA
Tarbell, NJ
机构
[1] Harvard Univ, Sch Med, Dept Radiat Oncol, Joint Ctr Radiat Therapy, Boston, MA 02215 USA
[2] Childrens Hosp, Dept Ophthalmol, Boston, MA 02115 USA
关键词
retinoblastoma; stereotactic radiotherapy; intensity modulation; noncoplanar arcs;
D O I
10.1118/1.598317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The proximity of the lens to the retina makes the treatment of retinoblastoma a challenge for external beam radiation therapy. The similar to 1 mm separation between the posterior edge of the lens and the anterior region of the retina causes a trade-off between coverage of the entire retina and excessive dose to the lens. A stereotactic, LINAC based, lens sparing technique for treating retinoblastoma is presented. The technique uses noncoplanar arcs with the lens at isocenter. A special noncircular collimator blocks the lens but it also causes the dose distribution to vary across the retina. A fluence modulation filter is used to reduce the dose inhomogeneity across the target. The resulting dose distribution is roughly hemispheric, providing both anterior coverage of the retina and lens blocking unlike conventional techniques. The method used to develop the collimator and filter assembly is presented. Dosimetry of the assembly was carried out using radiochromic film, and the results were entered in a treatment planning system. The dose distribution as measured in a phantom is provided and compared to calculations. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1438 / 1442
页数:5
相关论文
共 9 条
[1]  
BLANCHE EL, 1996, INT J RADIAT ONCOL, V35, P45
[2]   AN ANTERIOR APPOSITIONAL ELECTRON FIELD TECHNIQUE WITH A HANGING LENS BLOCK IN ORBITAL RADIOTHERAPY - A DOSIMETRIC STUDY [J].
BORGER, F ;
ROSENBERG, I ;
VIJAYAKUMAR, S ;
VIRUDACHALAM, R ;
SCHNEIDER, D ;
LANGMUIR, V ;
CHEN, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :795-804
[3]   AN EXTERNAL BEAM TREATMENT TECHNIQUE FOR RETINOBLASTOMA [J].
CHIN, LM ;
HARTER, KW ;
SVENSSON, GK ;
CASSADY, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (02) :455-460
[4]   A PROBLEM IN ROTATION THERAPY WITH X-RAYS [J].
CORMACK, AM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (04) :623-630
[5]   EXTERNAL BEAM IRRADIATION FOR RETINOBLASTOMA - PATTERNS OF FAILURE AND DOSE-RESPONSE ANALYSIS [J].
FOOTE, RL ;
GARRETSON, BR ;
SCHOMBERG, PJ ;
BUSKIRK, SJ ;
ROBERTSON, DM ;
EARLE, JD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (03) :823-830
[6]   External beam radiation for retinoblastoma: Results, patterns of failure, and a proposal for treatment guidelines [J].
Hernandez, JC ;
Brady, LW ;
Shields, JA ;
Shields, CL ;
DePotter, P ;
Karlsson, UL ;
Markoe, AM ;
Amendola, BE ;
Singh, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (01) :125-132
[7]   ADAPTATION AND VERIFICATION OF THE RELOCATABLE GILL-THOMAS-COSMAN FRAME IN STEREOTAXIC RADIOTHERAPY [J].
KOOY, HM ;
DUNBAR, SF ;
TARBELL, NJ ;
MANNARINO, E ;
FERARRO, N ;
SHUSTERMAN, S ;
BELLERIVE, M ;
FINN, L ;
MCDONOUGH, CV ;
LOEFFLER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (03) :685-691
[8]   THE USE OF A RADIOCHROMIC DETECTOR FOR THE DETERMINATION OF STEREOTAXIC RADIOSURGERY DOSE CHARACTERISTICS [J].
MCLAUGHLIN, WL ;
SOARES, CG ;
SAYEG, JA ;
MCCULLOUGH, EC ;
KLINE, RW ;
WU, A ;
MAITZ, AH .
MEDICAL PHYSICS, 1994, 21 (03) :379-388
[9]   RETINOBLASTOMA - MODIFICATION IN RADIATION-THERAPY TECHNIQUE [J].
WEISS, DR ;
CASSADY, JR ;
PETERSEN, R .
RADIOLOGY, 1975, 114 (03) :705-708