Fetal brain volumetry through MRI volumetric reconstruction and segmentation

被引:65
作者
Gholipour, Ali [1 ,2 ]
Estroff, Judy A. [1 ,2 ]
Barnewolt, Carol E. [1 ,2 ]
Connolly, Susan A. [1 ,2 ]
Warfield, Simon K. [1 ,2 ]
机构
[1] Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
Fetal MRI; Brain volumetry; Image reconstruction; Segmentation; LEVEL-SET APPROACH; CEREBRAL BIOMETRY; IMAGES; PREGNANCY; FETUSES;
D O I
10.1007/s11548-010-0512-x
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Purpose Fetal MRI volumetry is a useful technique but it is limited by a dependency upon motion-free scans, tedious manual segmentation, and spatial inaccuracy due to thick-slice scans. An image processing pipeline that addresses these limitations was developed and tested. Materials and methods The principal sequences acquired in fetal MRI clinical practice are multiple orthogonal single-shot fast spin echo scans. State-of-the-art image processing techniques were used for inter-slice motion correction and super-resolution reconstruction of high-resolution volumetric images from these scans. The reconstructed volume images were processed with intensity non-uniformity correction and the fetal brain extracted by using supervised automated segmentation. Results Reconstruction, segmentation and volumetry of the fetal brains for a cohort of twenty-five clinically acquired fetal MRI scans was done. Performance metrics for volume reconstruction, segmentation and volumetry were determined by comparing to manual tracings in five randomly chosen cases. Finally, analysis of the fetal brain and parenchymal volumes was performed based on the gestational age of the fetuses. Conclusion The image processing pipeline developed in this study enables volume rendering and accurate fetal brain volumetry by addressing the limitations of current volumetry techniques, which include dependency on motion-free scans, manual segmentation, and inaccurate thick-slice interpolation.
引用
收藏
页码:329 / 339
页数:11
相关论文
共 31 条
[1]
[Anonymous], 1999, Level Set Methods and Fast Marching Methods: Evolving Interfaces in Computational Geometry, Fluid Mechanics, Computer Vision, and Materials Science
[2]
MEASUREMENT OF FETAL LIVER, BRAIN AND PLACENTAL VOLUMES WITH ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING [J].
BAKER, PN ;
JOHNSON, IR ;
GOWLAND, PA ;
HYKIN, J ;
ADAMS, V ;
MANSFIELD, P ;
WORTHINGTON, BS .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (01) :35-39
[3]
Fetal brain/liver volume ratio and umbilical volume flow parameters relative to normal and abnormal human development [J].
Boito, S ;
Struijk, PC ;
Ursem, NTC ;
Fedele, L ;
Wladimiroff, JW .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (03) :256-261
[4]
Geodesic active contours [J].
Caselles, V ;
Kimmel, R ;
Sapiro, G .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (01) :61-79
[5]
The assessment of normal fetal brain volume by 3-D ultrasound [J].
Chang, CH ;
Yu, CH ;
Chang, FM ;
Ko, HC ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09) :1267-1272
[6]
Fetal MRI: A developing technique for the developing patient [J].
Coakley, FV ;
Glenn, OA ;
Qayyum, A ;
Barkovich, AJ ;
Goldstein, R ;
Filly, RA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (01) :243-252
[7]
Endres LK, 2001, J ULTRAS MED, V20, P1265
[8]
Fetal cerebral biometry: normal parenchymal findings and ventricular size [J].
Garel, C .
EUROPEAN RADIOLOGY, 2005, 15 (04) :809-813
[9]
Imaging the fetus: When does MRI really help? [J].
Garel, Catherine .
PEDIATRIC RADIOLOGY, 2008, 38 (Suppl 3) :S467-S470
[10]
Gholipour A., 2009, MICCAI WORKSH IM AN, P45